English
TROUBLESHOOTING GUIDE
Problem | Possible Causes | Solution | |
|
|
| |
“ADD WATER” | Low water level or lack of water. | Add water and the ice maker will | |
indicator light turns on. | operate automatically. | ||
| |||
|
|
| |
There is no indication | Disconnection of plug. | Check that the plug is plugged | |
on the control panel. | into the electrical outlet. | ||
| |||
|
|
| |
|
| Turn off the ice maker, pull out | |
|
| the electric plug, fill it with water | |
|
| if needed, replace the plug and | |
|
| then restart the unit. or | |
|
| Inspect relative parts; remove | |
| Electrical Power Surge | the drain cap on the back of | |
“Ice Full” and “Add | or | the unit and drain out a small | |
amount of water. Replace the | |||
Water” indicators light |
| ||
There may be air in the lines or | drain cap and attempt to use the | ||
up simultaneously. | |||
the lines are blocked. The water | unit again. | ||
| |||
| tank cannot detect water level. | or | |
|
| Check if ice is blocking the ice | |
|
| pusher. Turn off the unit; let the | |
|
| ice melt and restart. Otherwise, | |
|
| call Customer Service at the | |
|
| number below. | |
|
|
| |
The “Ice Full” indicator | The ice basket is full. | Remove ice from the ice storage | |
light is on. | basket to make more. | ||
| |||
|
|
| |
|
| Plug the unit into a standard | |
| Power is not being supplied | 110/120 Volt, 60 Hertz power | |
The unit does not | to the unit. The ambient | source. Please run the appliance | |
operate. | temperature or the water | in temperatures below 90°F | |
| temperature is too high. | and/or pour colder water into | |
|
| the water reservoir. | |
|
|
| |
Ice blockage. No ice is |
| Turn off the machine. Start the | |
Making ice takes too much time. | machine after the ice block | ||
being made. | melts. Or change the size | ||
| |||
|
| selector to smaller ice cubes. | |
|
|
| |
The icemaking cycle | There is refrigerant leakage. A | Consult a qualified technician | |
seems normal but no ice | pipe in the cooling system is | or call Customer Service at the | |
is produced. | blocked. | number below. | |
|
|
|
Note: There is protective circuitry inside this appliance to protect the circuitry from overheating. The appliance will automatically shut down to prevent damage if activated. Please disconnect power cord and restart after 30 minutes of cooling down time.
For CURTIS Customer Service, please call: 1-800-968-9853
11