Image IMSB53950 user manual Wiring the Hydrotherapy Spa

Models: IMSB53950

1 24
Download 24 pages 14.67 Kb
Page 8
Image 8
Wiring the Hydrotherapy Spa

Wiring the Hydrotherapy Spa

This procedure must be performed by a qualified, licensed electrician in accrodance with the nation- al electric code, and with all local, state, and feder- al electric code. Under no circumstances should the hydrotherapy spa be wired by someone other than a qualified electrician.

Before you have the spa wired, make sure it is in the desired position, and that it can be easily serviced, if needed.

The spa operates on a 240 volt power source. It must be wired directly into a grounded circuit with a 45 amp circuit breaker and a Ground Fault Circuit Interrupter (GFCI) capable of carrying 45 amps. No other appli- ance should be on the same circuit.

A wire connector is provided on the electronics pack of the spa to connect a minimum No. 6 AWG (13.3 mm2) solid copper conductor between the spa and any metal equipment, electrical enclosure made of metal, metal water pipes, or conduit within five feet of the spa.

Three options for wiring the spa are shown at the right. A wiring diagram is also found on the inside of the electronics pack for reference.

Option 1

 

 

 

 

 

 

 

Main Panel

 

 

 

 

 

 

Spa

GFCI Circuit

 

Min. of

Breaker

 

 

 

 

5 feet*

 

 

 

 

 

 

 

 

 

Wire Length

Suggested Wire Size

 

 

 

5 Feet to 25 Feet

6 AWG

 

 

 

25 Feet to 50 Feet

4 AWG

 

 

 

 

 

More than 50 feet not recommended

*The hydrotherapy spa must be placed a minimum of five feet from the Main Panel.

Option 2

 

 

 

 

 

Wire

 

Wire

 

Main Panel

 

 

(A)

 

(B)

 

GFCI Circuit

Disconnect

Spa

 

Min. of

Breaker

 

 

 

 

 

5 feet*

 

 

 

 

 

 

 

 

 

 

Wire Length

 

Suggested Wire Size

 

A

B

 

 

5 Feet to 25 Feet

6 AWG

6 AWG

25 Feet to 50 Feet

4 AWG

4 AWG

 

 

 

50 Feet to 100 Feet

2 AWG

4 AWG

More than 100 feet not recommended

*The hydrotherapy spa must be placed a minimum of five feet from the Disconnect.

Option 3

 

 

 

 

 

 

Wire

 

Wire

 

 

Main Panel

Disconnect

 

(A)

(B)

Spa

 

Circuit

 

GFCI

Min. of

 

Breaker

 

 

 

 

 

 

5 feet*

 

 

 

 

 

 

 

 

 

 

 

Wire Length

 

Suggested Wire Size

 

 

A

B

 

 

 

 

5 Feet to 25 Feet

6 AWG

6 AWG

 

 

 

 

 

25 Feet to 50 Feet

4 AWG

4 AWG

 

 

 

 

 

50 Feet to 100 Feet

2 AWG

4 AWG

 

 

 

More than 100 feet not recommended

 

 

 

 

 

 

*The hydrotherapy spa must be placed a minimum of five feet from the Disconnect.

8

Page 8
Image 8
Image IMSB53950 user manual Wiring the Hydrotherapy Spa