SNMP Management Module LEDs

The SNMP Management Module features several LEDs. The LED functions are:

LNK/ACT

Glows green when a link is established on port.

 

Blinks green when data activity occurs.

FDX/COL

Glows yellow when port is in Full-Duplex mode.

 

Blinks yellow when port is operating in Half-

 

Duplex mode and collisions occur.

TEMP

Glows yellow when temperature of unit

 

surpasses a user-defined level.

PS

Glows yellow when one power supply module

 

malfunctions.

FAN A / FAN B

Glows yellow when a fan malfunctions.

DC Power Wiring, Replacing Power Supply Modules and Fans

DC Power Supply Module Wiring Instructions

The following diagram shows the wiring configuration for a -48 VDC power supply module for the iMediaChassis/3.

NOTE

Incorrect wiring will result in chassis malfunction.

The iMediaChassis/3 is compliant with Isolated Grounding Plane practices. The POSITIVE and NEGATIVE terminals are isolated from chassis ground and must have a ground reference at the power-sourcing equipment.

19

Page 23
Image 23
IMC Networks 20, iMediaChassis/3, iMediaChassis/6 operation manual Glows yellow when temperature of unit