SNMP Management Modules include two twisted pair ports, one for management and one reserved for future use. The Management Module also features a DB-9 serial port, and supports SNMP V1/V2c.

Installing Management and Application Modules

Installing Applications Modules

To install a module:

1.Remove the blank bracket (if present) covering the slot where the module will be installed. IMC Networks recommends installing blank brackets in unused module slots.

2.Slide the module into the chassis using the card guides.

3.Secure the module to the chassis by tightening the captive screw. (Refer to the documentation shipped with the module for configuration information.)

4.When installing modules observe ESD precautions, refer to the Electrostatic Discharge Precautions section.

In order to manage an iMediaChassis series, the SNMP Management Module needs to be installed in the appropriate slot of the chassis.

Install the iMediaChassis/6 slot into the first slot on the far left of the chassis.

NOTE

This slot is ONLY for the Management Module; do not install Application Modules such as media conversion and mode conversion modules into this slot.