Impex IGS 16 manual High-Low Station Cable Looping See Diagram

Models: IGS 16

1 33
Download 33 pages 5.49 Kb
Page 22
Image 22

STEP 14 High-Low Station Cable Looping (See Diagram 14)

A.)

Slide a Ball Stopper (#70) onto the 262” High-Low Cable (#53). Slide and Pull the Cable

 

Strap Bracket (#45) onto the Cable. Secure the Bracket with a M8 x 1 ¼” Allen Bolt (#110)

 

and M8 Aircraft Nut (#124).

B.)

Attach the Cable in between the pre-assembled two Small Pulleys (#85) on the

 

Sliding Pulley Frame (#22). Note: The Ball Stopper should be in front of the Sliding

 

Pulley Frame.

C.)

Draw the Cable through the Sliding Pulley Frame then pull upward to the Pulley on

 

the top opening of the Sliding Pulley Vertical Beam (#9).

D.)

Draw the Cable over the Pulley then pull forward to the Pulley on the rear opening on

 

the Upper Frame (#5).

E.)

Draw the Cable over the Pulley then pull downward. Attach the Cable to the Pulley

 

on the Single Floating Pulley Bracket (#23) installed in Step12.

F.)

Draw the Cable underneath the Pulley then pull upward to the Pulley on the upper

 

Rear Vertical Frame (#4). Let the Single Floating Pulley Bracket hanging for now.

G.) Draw the Cable around the Pulley then drop the Cable inside the tube downward

 

through the Rear Vertical Frame to the Pulley on the bottom opening. Remove the

 

Pulley to get the Cable out then reinstall the Pulley. Draw the Cable underneath the

 

Pulley then pull upward to the bracket on the Sliding Pulley Frame (#21).

H.)

Attach the Cable head to the bracket. Secure the Cable head in place with one M10

 

x 1 1/8” Allen Bolt (#99) and M10 Aircraft Nut (#125).

I.)

Connect the Single Handle (#35) to the Cable Strap Bracket (#45) with a Hook (#41).