Ducting or Recirculation fitting

Ducting or Recirculation fitting

Ducting fitting

The cooker hood can be ducted to the outside using either rigid or flexible fire retardant ducting of 120 or 150 mm. The choice is left to the installer. When 120 mm ducting is to be used it will be necessary to install the reduction flange item A on the air outlet fig. 4.

The installer should provide suitable ducting and sealing material for the installation.

The cooker hood can also be ducted to the outside through one of the rectangular openings located in either side of the lower section of the chimney stack. In this case the deflector (item D) should be fitted into the spigot (item R) to close the aperture which is not used (fig. 5).

If the hood is provided with the charcoal filters fitted, the filters should be removed (see paragraph Maintenance).

Recirculation fitting

The filtered air is returned to the room through the two side grilles on U-shaped lower section I, which are either formed in the metal itself (fig. 6).

Fit the recirculation spigot item R into the round outlet on top of the canopy while pressing down on the spigot until it snaps into position.

Install the charcoal filters inside the canopy as instructed in paragraph Maintenance).