Image 6

Turn the knob to minimum and make sure (with the door closed) that the flame became smaller, but stable (about 3 o 4 mm). If the flame is not stable on the minimum setting, remove the knob, unscrew the screw from the control panel and remove it. Turn the screw

M” to adjust the thermostat minimum, turning it counter-clockwise if the flame is too low and clockwise if the flame is too high (Fig. G).

c)The grill burners has no regulation of the minimum.

N.B.: in the case of liquid gas, the regulation screw must be screwed in to the bottom.

Check that the flame does not turn off when you turn the tap quickly from high to low.

Attention: on completion of the above operation, please replace the current technical data label with a new one containing details of the gas which the appliance has now been converted to. The new technical data label is contained in the nozzles Kit supplied with the cooker.

Note: should the pressure of the gas used be different (or vary) from the recommended pressure, it is necessary to fit a suitable pressure regulator onto the inlet pipe in compliance with current National Regulations relative to “regulators for channelled gas”.

Burner and nozzles characteristics

Table 2

 

 

 

 

 

 

Liquid Gas

 

 

Natural Gas

 

 

 

 

 

 

 

 

 

 

 

 

Burner

Diameter

Thermal power

By-pass

Nozzle

 

Flow*

Nozzle

 

Flow*

 

(mm)

 

kW

1/100

1/100

 

1/100

 

 

 

 

g/h

 

l/h

 

 

(p.c.s.*)

(mm)

(mm)

 

(mm)

 

 

 

 

 

 

 

 

 

 

Nomin.

 

Reduc.

 

 

***

 

**

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front-Right

90

3.30

 

0.70

42

90

240

 

236

135

 

314

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear-Left

78

2.70

 

0.70

42

83

196

 

193

122

 

257

 

 

 

 

 

 

 

 

 

 

 

 

 

Front-Left

50

1.70

 

0.40

29

65

124

 

121

97

 

162

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear-Right

50

1.70

 

0.40

29

65

124

 

121

97

 

162

 

 

 

 

 

 

 

 

 

 

 

 

 

Oven

-

3.35

 

1.20

53

90

244

 

239

135

 

319

 

 

 

 

 

 

 

 

 

 

 

 

 

Grill

-

2.20

 

-

-

78

160

 

157

117

 

209

 

 

 

 

 

 

 

 

 

 

 

 

Supply

Nominal (mbar)

37**

 

 

28-30***

 

20

Minimum (mbar)

25**

 

 

20***

 

17

pressures

 

 

 

Maximum (mbar)

45**

 

 

35***

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*At 15°C and 1013 mbar-dry gas

**

Propane

P.C.S. = 50,37 MJ/Kg

***

Butane

P.C.S. = 49,47 MJ/Kg

 

Natural

P.C.S. = 37,78 MJ/m3

 

 

 

 

 

Technical characteristics

 

 

 

Mains frequency and voltage of the electric section and characteristics of the gas section

Model

 

Gas section

Electric section

 

 

 

 

 

 

 

 

Class

 

Rated power

Voltage

Power

 

 

kW (1)

(W)

 

 

 

 

 

 

 

 

 

 

KG 6407 BG/G

 

 

11,88 (864 g/h - G30)

 

 

KG 6407 WG/G

II2H3+

 

220-240V~ 50-60Hz

19

 

(848 g/h - G31)

KG 6407 XG/G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(1) The values in g/h refer to the capacities with liquid gas (Butane, Propane).