Installation

All instruction on the following pages must be carried out by a competent person (corgi registered) in compliance with gas safety (installation and use) regulation 1984.

Important: disconnect the cooker from the electrycity and gas supply when any adjustment, etc.

Positioning your appliance

Important: this appliance may be installed and used only in permanently ventilated rooms in compliance with current directives. The following precautions should be taken:

a)The room must be provided with an external exhaust system obtained with a hood or with an electric

installed or settled in rooms that are below the ground level, (cellar, etc.) whether the cans are empty or partially full. It is advisable to keep in the room only the can which is being used, and it must be placed away from direct heat sources (ovens, fireplaces, stoves, etc.) that could make the can reach temperatures higher than 50°C.

Levelling your appliance (only on a few models) Your cooker is supplied with feet for levelling the appliance.

If necessary, these feet can be screwed into the housings in the corners of the cooker base.

Mounting the legs (only on a few models)

ventilator that goes on automatically each time the unit is switched on.

In the case of chimneys or flues

Directly to the

with branches (for cookers)

exterior

b)The room must be provided with a system for air inflow which is necessary for a regular combustion. The air flow necessary for the combustion should be at least 2 m3/h for kW of installed power. The system may be realized by drawing the air directly from outside the building through a pipe that has at least a 100 cm2 useable section and which must not be accidently obstructed (Fig. A). And further it may be realized indirectly from other adjacent rooms which are provided with a ventilation pipe for the expulsion of the fumes to the outside of the building as foresaid, and which must not be part of the building in common use or

A

rooms with risk of fire, or bedrooms (Fig. B).

Detail A

Adjacent

Room to

 

room

be ventilated

Fig. A

Fig. B

 

Examples of ventilation openings

Increased opening between

for the comburent air

the door and and floor

c)During prolonged use of the appliance you may consider it necessary to open a window to the outside to improve ventilation.

d)The liquefied petroleum gases, which are heavier than air, stagnate towards the ground. Therefore, the rooms containing LPG cans must have openings towards the outside in order to allow the venting from the ground of eventual gas leak. Thus, the LPG cans must not be

Press-fit legs are supplied which fit under the base of your cooker.

Installation of the cooker

The appliance can be installed next to furniture units which are no taller than the top of the cooker hob. The wall in direct contact with the back panel of the cooker must be made of non-flammable material. During operation the back panel of the cooker could reach a temperature of 50°C above room temperature. For proper installation of the cooker, the following precautions must be taken:

a)The appliance can be placed in a kitchen, dining room or bedsit, but not in a bathroom.

b)All furniture around the appliance must be placed at least 200 mm from the top of the cooker, should the surface of the appliance be higher than the worktop of this furniture. Curtains should not be placed behind the cooker or less than 200 mm away from the sides of the appliance.

c)Any hoods must be installed according to the require- ments in the installation manual for the hoods them- selves.

d)If the cooker is installed beneath a wall cabinet, the latter must be situated at a minimum of 420 mm above the hob. The minimum distance between the worktop and kitchen units made of combustible material is 700 mm.

23