CD-7 thru CD-15 Infinity Corona Discharge Ozone Generator

2.G.F.C.I. has tripped.*

a.Check power cord and reset G.F.C.I.

3.Circuit breaker has tripped.*

a.Reset breaker.

*If G.F.C.I. or breaker continue to trip after reset, call for technical assistance.

Symptom: Ozone power” indicator light out.

1.If optional ORP is installed, ORP may have shut down the generator when ORP level reached setpoint.

a.Wait for ORP to come down. Generator will restart when ORP level is below set point.

2.Abnormal operating condition exists.

a.Check red fault indicator lights. Refer to corre- sponding symptom and corrective action.

Symptom: Vacuum” indicator light is on indicating out of range vacuum being supplied.

1.Injector not supplying adequate suction.

a.Check pump and ensure water is flowing through injector.

b.Check by-pass valve and adjust if necessary to obtain proper pressure differential in order to reestablish suction.

2.Injector supplying too much suction.

a.Check by-pass valve and adjust to obtain proper suction.

b.Check system back pressure and increase to reduce suction.

3.Another abnormal condition exists causing ozone out- put solenoid valve to be closed.

a.Check red fault indicator lights. Refer to corre- sponding symptom and corrective action.

b.Solenoid valve may be stuck in closed position. Free solenoid plunger and return system to normal operation.

Symptom: High coolant temperature” indicator light is on indicating ozone module temperature over 150°F.

1.Coolant water flow has been interupted.

a.Check all tubing connections, ensureing tight, leak free connections.

b.Trace tubing and look for blockage of flow.

c.Re-establish proper coolant water flow.

Symptom: High transformer temperature” indicator light is on indicating high voltage transformer temperature over 150°F.

1.Enclosure ventilation is blocked.

a.Check air filter on bottom left-hand side of enclosure for blockage.

b.Clear blockage or clean filter.

c.Restart system and allow transformer to cool. When temperature returns to normal system will return to normal operation.

2.Excessive ambient temperatures in installation area.

a.Generator should not be exposed to ambient temperatures above 100°F. Higher temperatures may damage generator components.

Symptom: Water backflow detected” indicator light is on.

1.Water has backed into generator from injector.

a.Establish proper water flow through injector and correct suction.

b.Drain Back Flow Preventer by first routing drain tubing out of cabinet.opening cabinet and opening 1/4" stainless steel ball valve.

c.After water has completly drained close drain valve, secure cabinet door and restart system.

Symptom: CD Module is not operating. Ozone output has dropped.

1.No power to the generator module from the power supply:

a.Check H.V. cables for breaks or loose connections, replace if necessary.

b.Check for power at input terminals of the H.V. transformers.*

c.Check ozone power relay for loose connections or faulty operation.

*CAUTION: HIGH VOLTAGE.

Symptom: No air flow through the generator.The air flow meter indicates 0 scfh flow.

1.Flowmeter control valve is improperly set:

a.Open flowmeter valve until proper air flow is indicated (~8 scfh for CD-7, ~14 scfh for CD-15).

2.Air compressor is not operating properly.

a.Listen for air compressor operation.

b.Check all tubing connections from the air compres- sor through the system for leaks.

SECTION 5

Replacement Parts and Order Information

5A. Ordering information:

For replacement parts call DEL at 1-800-676-1335. Be prepared with the following information:

·Customer Name ·Customer Address

·DEL Model Number ·DEL Serial Number

·Date Purchased ·Proof of Purchase

5B. Standard replacement parts list:

1.

Compressor rebuild kit, CD-7

9-1007

2.

Compressor rebuild kit, CD-15

9-1015

3.

Ventilation air filter

7-0401

4.

High voltage electrode

9-0540

5.

Ozone tubing, Teflon

7-0126

6.

Ozone tubing, Stainless Steel

8-0098

7.

Ozone module gasket (1 ea.)

7-0801

8.

Installation & Operations Manual