Hoistway and Cab Configurations INFINITY
Residential Elevator

Choice of Five Variations

Important Note: Finished hoistway dimensions must include the drywall. Determine the fire

rating of the hoistway, the type and layers of sheet rock and build only off shop drawings

specific to your project.

Available Cab Dimensions (Clear Inside): 35" x 48" 35" x 54" 35" x 60"

Type 1 (S) - Enter/Exit Same Side

Clear Cab
Len
g
th Finished
Hoistwa
y
Len
g
th
48" 56 1/4"
54" 62 1/4"
60" 68 1/4"
X X + 8 1/4"
LENGTH
WIDTH

Type 2 (W) - Enter/Exit Opposite Side

Clear Cab
Len
g
th Finished
Hoistwa
y
Len
g
th
48" 54 3/4"
54" 60 3/4"
60" 66 3/4"
X X + 6 3/4"
LENGTH
WIDTH

Type 3 (WS) - 90oEnter/Exit

Clear Cab
Len
g
th Finished
Hoistwa
y
Len
g
th Side Entrance
Center Lines
48" 56 7/8" 33 7/8"
54" 62 7/8" 39 7/8"
60" 68 7/8" 45 7/8"
X X + 8 7/8" X + 14 1/8"
see chart
LENGTH
WIDTH

Type 4 (WS) - 90oEnter/Exit

Clear Cab
Len
g
th Finished
Hoistwa
y
Len
g
th Side Entrance
Center Lines
48" 56 7/8" 33 7/8"
54" 62 7/8" 39 7/8"
60" 68 7/8" 45 7/8"
X X + 8 7/8" X + 14 1/8"
see chart
LENGTH
WIDTH
CPG-INFVER01 © 2004, Concord Elevator Inc.