Parameter | Specification | Unit | QA Test | Conditions | Notes | |
Limits | ||||||
|
|
|
|
| ||
THD at Max. Output Power | less than 10 | % |
| Maximum Output Power | Maximum THD as a result of limiting. | |
|
|
|
|
|
| |
Output Volume Control |
|
|
|
|
| |
Volume Control Pot | YES |
| mounted on amp panel |
| ||
Detent (center/#) | NO |
|
|
| ||
Taper (lin/log) | log A taoer |
|
|
| ||
@ minimum setting | no output |
|
|
|
| |
|
|
|
|
|
| |
Input/Output Phase |
|
|
|
|
| |
Line Input vs. Hi Input | N/A | ° |
|
|
| |
Lo/Hi Input vs. Lo/Hi Output | N/A | ° |
|
|
| |
|
|
|
|
|
| |
Input/Output |
|
|
|
|
| |
Line In (L,C,R,AC3,Mono) | Stereo |
| RCA phono jack, gold plated |
| ||
LFE In | YES |
| Shared with "R" Line In jack |
| ||
|
|
|
|
|
| |
Signal Sensing (ATO) |
|
|
|
|
| |
YES |
|
|
| |||
ATO Input Test Frequency | 100 | Hz |
|
|
| |
ATO Input Threshold | 2 | mV | typ. |
| LPF "On", BOS "Off" | |
ATO Low Pass cutoff | 400 | Hz | 450 | LPF "On", BOS "Off" | ||
|
|
|
| Amp connected and AC on, |
| |
ATO | 1 | ms | 10 | then input signal applied ( 1 W |
| |
|
|
|
| output ) |
| |
Auto Mute / | 10 | minutes | 5 < t < 15 | Time before muting, after signal |
| |
is removed |
| |||||
|
|
|
|
|
| |
Power on Features |
|
|
|
|
| |
Power on Delay time | greater than | 2sec. |
| AC Power Applied |
| |
Power on LED | YES |
|
| |||
| cabinet |
| ||||
|
|
|
|
| ||
Normal On/Off | green / red | color |
| ATO mode only |
| |
ATO | color |
| "Active": green; "Standby": red |
| ||
|
|
|
|
|
| |
|
|
|
|
|
| |
Transients/Pops |
|
|
|
|
| |
ATO Transient | 5 |
| @ Speaker Output |
| ||
30 |
| @ Speaker Output | AC Line cycled from OFF to ON | |||
30 |
| @ Speaker Output | AC Line cycled from ON to OFF | |||
|
|
|
|
|
| |
Efficiency |
|
|
|
|
| |
10 | Watts | typ. | @ nom. line voltage |
| ||
AC Power Cons.@1W | 12 | Watts | typ. | @ nom. line voltage |
| |
Power Cons.@rated power | 473 | Watts | typ. | @ nom. line voltage | Input power measured is REAL Watts, not VA | |
|
|
|
|
|
| |
Efficiency | 63 | % | typ. | @ nom. line voltage |
| |
|
|
|
|
|
| |
Protection |
|
|
|
|
| |
Short Circuit Protection | YES |
| Direct short at output |
| ||
Thermal Protection | YES |
| threshold ~ 65 deg. C at panel |
| ||
|
|
|
|
|
| |
DC Offset Protection | YES |
| DC present at Speaker Out | Relay for driver/fire protection | ||
| leads | |||||
|
|
|
|
| ||
Line Fuse Rating ( 120 V ) | 3.15 | Amps |
| Type ADL or MDL | Fuse holder on inside surface of amp panel | |
|
|
|
|
|
| |
AC Power & Transformer |
|
|
|
|
| |
Power cord length | 9 | feet |
| Double insulated cord, |
| |
| AWG#18 |
| ||||
|
|
|
|
|
3