Infinity TSS-SUB4000 service manual Parameter

Models: TSS-SUB4000

1 32
Download 32 pages 16.25 Kb
Page 4
Image 4
Manual background

TSS-SUB4000

 

 

 

 

 

 

Parameter

Specification

Unit

QA Test

Conditions

Notes

Limits

 

 

 

 

 

THD at Max. Output Power

less than 10

%

 

Maximum Output Power

Maximum THD as a result of limiting.

 

 

 

 

 

 

Output Volume Control

 

 

 

 

 

Volume Control Pot

YES

--

 

mounted on amp panel

 

Detent (center/#)

NO

--

 

 

 

Taper (lin/log)

log A taoer

--

 

 

 

@ minimum setting

no output

 

 

 

 

 

 

 

 

 

 

Input/Output Phase

 

 

 

 

 

Line Input vs. Hi Input

N/A

°

 

 

 

Lo/Hi Input vs. Lo/Hi Output

N/A

°

 

 

 

 

 

 

 

 

 

Input/Output

 

 

 

 

 

Line In (L,C,R,AC3,Mono)

Stereo

--

 

RCA phono jack, gold plated

 

LFE In

YES

--

 

Shared with "R" Line In jack

 

 

 

 

 

 

 

Signal Sensing (ATO)

 

 

 

 

 

Auto-Turn-On (yes/no)

YES

--

 

 

 

ATO Input Test Frequency

100

Hz

 

 

 

ATO Input Threshold

2

mV

typ.

 

LPF "On", BOS "Off"

ATO Low Pass cutoff

400

Hz

450

ATO-LPF for noise immunity

LPF "On", BOS "Off"

 

 

 

 

Amp connected and AC on,

 

ATO Turn-on time

1

ms

10

then input signal applied ( 1 W

 

 

 

 

 

output )

 

Auto Mute / Turn-OFF Time

10

minutes

5 < t < 15

Time before muting, after signal

 

is removed

 

 

 

 

 

 

 

Power on Features

 

 

 

 

 

Power on Delay time

greater than

2sec.

 

AC Power Applied

 

Power on LED

YES

--

 

Bi-color LED located on front of

 

 

cabinet

 

 

 

 

 

 

Normal On/Off

green / red

color

 

ATO mode only

 

ATO

--

color

 

"Active": green; "Standby": red

 

 

 

 

 

 

 

 

 

 

 

 

 

Transients/Pops

 

 

 

 

 

ATO Transient

5

mV-peak

 

@ Speaker Output

 

Turn-on Transient

30

mV-peak

 

@ Speaker Output

AC Line cycled from OFF to ON

Turn-off Transient

30

mV-peak

 

@ Speaker Output

AC Line cycled from ON to OFF

 

 

 

 

 

 

Efficiency

 

 

 

 

 

Stand-by Input Power

10

Watts

typ.

@ nom. line voltage

 

AC Power Cons.@1W

12

Watts

typ.

@ nom. line voltage

 

Power Cons.@rated power

473

Watts

typ.

@ nom. line voltage

Input power measured is REAL Watts, not VA

 

 

 

 

 

 

Efficiency

63

%

typ.

@ nom. line voltage

 

 

 

 

 

 

 

Protection

 

 

 

 

 

Short Circuit Protection

YES

--

 

Direct short at output

 

Thermal Protection

YES

--

 

threshold ~ 65 deg. C at panel

 

 

 

 

 

 

 

DC Offset Protection

YES

--

 

DC present at Speaker Out

Relay for driver/fire protection

 

leads

 

 

 

 

 

Line Fuse Rating ( 120 V )

3.15

Amps

 

Type ADL or MDL

Fuse holder on inside surface of amp panel

 

 

 

 

 

 

AC Power & Transformer

 

 

 

 

 

Power cord length

9

feet

 

Double insulated cord,

 

 

AWG#18

 

 

 

 

 

 

3

Page 4
Image 4
Infinity TSS-SUB4000 service manual Parameter