Resetting the lamp timer

Be extremely careful when removing the lamp housing. In the unlikely event that the lamp ruptures, small glass fragments may be generated. The lamp module is designed to contain most of these fragments, but use caution when removing it. Before replacing a ruptured lamp, clean the lamp compartment and dispose of cleaning materials. Wash hands after lamp replacement.

Hg – Lamp contains mercury. Manage in accordance with local disposal laws. See www.lamprecycle.org.

5Detach the lamp connector from the projector by gently pulling the con- nector until it is disconnected from the projector.

6Carefully remove the lamp module by grasping and lifting the metal bail wire. Dispose of the lamp in an environmentally proper manner.

7Install the new lamp module, making sure that it is properly seated. Be careful not to touch the interior components of the projector.

8Snap the bail wire back into its flat position against the lamp module.

9Re-attach the lamp connector to the projector. Make sure the connector is fully inserted.

10Tighten the screw on the lamp module.

11Replace the lamp door.

12Plug in the power cable then press the Power button to turn the projec- tor back on, then reset the lamp hour timer.

Resetting the lamp timer

To reset the lamp timer, navigate to the Settings>Service menu and select Reset Lamp Hours.