A write request example:
(AAA####) where
( starts the command
AAA denotes the command
####denotes the value to be written (leading zeros not necessary)
) ends the command
Some commands have ranges, while others are absolute. If a number greater than the maximum range is received, it is automatically set to the maximum number for that function. If a command is received that is not understood, a "?" is returned. With absolute settings, "0" is off,
To assure the projector can process a command, wait 3 seconds before entering the next command.
Write Command Examples
| Function |
| Command |
| Response |
| Brightness |
| (BRT10) |
| Sets the brightness |
|
|
|
|
| to 10 |
| Freeze |
| (FRZ1) or |
| Freezes the display |
|
|
| (FRZ8888) |
|
|
| Power |
| (PWR0) |
| Turns power off |
| Power |
| (PWR1) |
| Turns power on |
| Error Conditions |
|
|
|
|
Not all commands are supported for all projectors. If an unsupported command is issued, the command will be ignored. If a command is received that is not understood, a ‘?’ character will be returned indicating the command was not understood.
Limitations
The CLI cannot respond to commands coming in at a
The following table lists the
Note: Specified commands and values apply to the LP720 with version 3.04 software or higher. The version number of the software is the first number listed in the upper right corner of the
For absolute command value ranges of 0 - 1, 0 = "Off" and