4Loosen the two captive screws on the lamp door and lift the door off.

Be extremely careful when removing the lamp housing. In the unlikely event that the lamp ruptures, small glass fragments may be generated. The lamp module is designed to contain most of these fragments, but use caution when removing it. Before replacing a ruptured lamp, clean the lamp compartment and dispose of cleaning materials. Wash hands after lamp replacement.

Hg – Lamp contains mercury. Manage in accordance with local disposal laws. See www.lamprecycle.org.

4Loosen the two captive screws on the lamp door and lift the door off.

5Loosen the two captive screws that attach the lamp housing to the projector.

6Carefully remove the lamp housing. Dispose of the lamp in an environmentally proper manner.

7Install the new lamp housing and tighten the screws.

8Replace the lamp door.

9Plug in the power cord and press the Power button to turn the projector back on.

10To reset the lamp hour timer, navigate to the Status and Service menu and select Reset Lamp Hours. See page 32 for details.

loosen screw

loosen screw

35