MAINTENANCE SECTION
TROUBLESHOOTING GUIDE
Trouble Probable Cause Solution
Sluggish operation Dirt or oil gum accumulation on
internal parts
In a well ventilated area, pour 3 cc of a clean, suit-
able, cleaning solution into the air inlet and oper-
ate for 30 seconds. After flushing, lubricate with
the recommended oil.
Loss of power Worn Valve Replace the Valve.
Loss of efficiency Worn Piston and/or accessory Replace worn parts.
SAVE THESE INSTRUCTIONS. DO NOT DESTROY.