TROUBLE SHOOTING

ARO￿STOP valve does not close when it should.

Improper adjustment. Readjust and test.

Change has occurred in operating conditions (i.e. decrease in sup￿

ply pressure). Readjust and test.

ARO￿STOP valve closes for no apparent reason.

Change has occurred in operating conditions (i.e. increase in sup￿ ply pressure). Readjust and test.

Material supply has been interrupted. Insure constant material sup￿ ply.

Air supply turned on too quickly. Depress reset button. Pump continues to cycle after ARO￿STOP valve closes.

Foreign matter on sealing surface of ARO￿STOP valve. Disas￿

semble and clean valve as described in Service Section.

NOTE: Very slow cycling may occur even after ARO￿STOP valve closes. This is normal.

ARO￿STOP valve does not start when reset button is depressed.

Improper adjustment. Readjust and test.

WARNING

Always disconnect and relieve air pressure from the ARO￿STOP valve before removing it from the system for servicing.

SERVICE INSTRUCTIONS

DISASSEMBLY:

1.Unscrew the rear adapter assembly from the sleeve assembly. This allows accessibility to the 22836 valve assembly and the 22207 spring.

2.Clean all parts and inspect for damage or wear. Replace the 22836 valve assembly or 22207 spring if necessary.

ASSEMBLY:

1.Reassemble the 22836 valve assembly and the 22207 spring as shown in the view.

2.Apply thread locking compound to the threads of the rear adapter assembly and tighten to the sleeve assembly using 30 ￿ 40 ft lb (40.7 ￿ 54.2 Nm) torque.

NOTE: Parts other than 22836 valve assembly and 22207 spring, are not accessible for service and should not be disassembled.

22836

22207

PN 103994

PAGE 2 OF 2

23644￿400

Page 2