OPERATOR'S MANUAL

300-301

300-301 FLOW GUN 1/4 inch SEAT TUNGSTEN CARBIDE

IMPORTANT: READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING,

OR SERVICING THIS EQUIPMENT

WARNING:

Always wear eye protection when operating this gun. Do not use damaged, frayed or deteriorated material hoses or fittings.

SERVICE KITS

Use only Johnstone replacement parts to insure compatibility and longest life.

300-301RK

Repair Kit

300-919

Valve Rod Assembly

WARNING:

DO NOT OPERATE FLOW GUN AT PRESSURES ABOVE RECOMMENDED MAXIMUM OF 4000PSI (272 BAR) MATERIAL AND 100PSI (6.8 BAR) AIR.

SPECIFICATIONS

Material Inlet Port Size

3/8" NPT

Material Outlet

1/4” orifice

Nozzle connection

400-667 Collar

MAINTENANCE SCHEDULE

DAILY:

Check for material leakage.

Check for Frayed or damaged hoses.

Depressurize when not in use.

OPERATION

Supply material to the flow gun.

Adjust Material Pressure to flow gun until desired material flow is achieved. (Material Regulator) Adjust the trigger spring pressure until the Flow Gun closes while under pressure. Turn the Adjusting screw clockwise to increase pressure and counter-clockwise to decrease pressure.

COLLAR

ADJUSTING

 

SCREW

BODY

TRIGGER

3/8” NPT MATERIAL INLET

REPLACEMENT PROCEDURE

Depressurize the Flow Gun

Disconnect the 3/8” NPT fitting from the Gun inlet and remove the Nozzle.

Connect new Flow gun to the 3/8” NPT. Install new nozzle.

To bleed air out of the Flow Gun- Operate the Flow Gun until the air stops coming out.

Johnstone Dispensing Systems

1872 Enerprise Drive PH (248) 293-5700

 

 

 

 

300-301.doc

Rochester Hills MI 48309 FX (248 ) 293-5800

March15, 2000

Page 1
Image 1
Ingersoll-Rand 300-301 specifications Operators Manual, Flow GUN 1/4 inch Seat Tungsten Carbide