651616-XPAGE 4 OF 8
LIFT / RAM INSTALLATION
WARNING Failureto properly installthe lift assembly can re -
sult in severe personal injury and property damage. Read the
warning on page 2.
1. Thisassembly is shipped in two cartons: a) the follower plate b) the
ram / lift. Assemble the vertical rods to the Horizontal Bracket to
match the pump and follower plate combination.
2. Establishthe desired location for the lift / ram and pay special atten-
tionto work area above, this area above the lift must be open, with-
out obstructions and safely away from any electrical devices.
3. THE LIFT MOUNTING PLATEBASE MUST BE SECURELY AN-
CHOREDTO THE CONCRETE FLOOR. The mounting plate itself
canbe used for a template for establishing the proper anchor loca-
tions.
4. Placethe pump on the follower plate and align the pump and follow-
er plate on the base and assemble the appropriate vertical rods.
5. Install the check and follower plate air hose from the control valve.
6. Assemble the vent plug to the follower plate.
7. When large pump motors are used, the horizontal arm should be
turnedover to accommodate the F-R-L which can then be mounted
on top.
NOTE:The ram was tested at the factory. The unit should be generally
checkedover for leakage, because the fittings on the system may have
loosened in shipment.
67196-X
66667-X66517-X
66668-X
66516-X
ARO 55 GALLON FOLLOWER PLATES
17-7/8’’(454.0 mm)
(Referto the chart on page 3)
67195-X
14’’(355.6 mm)
17-7/8’’(454.0 mm)
14’’(355.6 mm)
17-7/8’’(454.0 mm)
14’’(355.6 mm)
17-7/8’’(454.0 mm)
14’’(355.6 mm) 17-7/8’’(454.0 mm) 17-7/8’’(454.0 mm)
FIGURE 3