ELECTRICAL CONNECTION DIAGRAM
|
|
|
| 3 PHASE, 50 / 60 Hz |
|
|
| |||
| 6 | 5 | 4 |
| 6 | 5 | 4 |
|
|
|
| 9 | 8 | 7 |
| 9 | 8 | 7 |
|
|
|
| 3 | 2 | 1 |
| 3 | 2 | 1 | 1 | 2 | 3 |
GROUND | LINE A | LINE B | LINE C | GROUND | LINE A | LINE B | LINE C | LINE A | LINE B | LINE C |
| SUPPLY 220 V |
| SUPPLY 440 V | SUPPLY 550 V | ||||||
| SUPPLY 230 V |
| SUPPLY 460 V | SUPPLY 575 V | ||||||
| *(50 Hz 1.8 - 2.0 amp.) |
| *(50 Hz .9 - 1.0 amp.) | *(60 Hz X.X - X.X amp.) | ||||||
| *(60 Hz 1.6 - 2.0 amp.) |
| *(60 Hz .8 - 1.0 amp.) |
|
|
|
* RECOMMENDED OVERLOAD SETTING.
TO REVERSE ROTATION: INTERCHANGE ANY TWO LEADS.
WARNING: BE SURE THE ELECTRICAL POWER SUPPLY IS OFF BEFORE MAKING ANY ELECTRICAL WIRING CONNEC- TIONS.
WARNING: FAILURE TO PROPERLY GROUND THE MOTOR MAY CAUSE SERIOUS INJURY TO PERSONNEL.
DO NOT BLOCK THE AIR FLOW TO OR FROM THE MOTOR COOLING FAN. DO NOT DAMAGE THE MOTOR FAN COVER. KEEP SMALL OBJECTS CLEAR OF THE OPENINGS IN THE FAN COVER.
Connect the motor starter to the motor as shown in the wiring dia- gram. The minimum wire size should be AWG No. 14, or equiva- lent, (4107 circular mil) and conform to local / national regulations governing the use of this type of electrical equipment.
Once the motor is connected, turn on the power supply. If the
M107
26
spindle fails to rotate or rotates in the wrong direction,
SET–UP PROCEDURE
WARNING: Keep clear of rotating end of unit with hands and/or clothing.
•Shut off air supply to tool.
•Loosen screw (41), releasing cover (33).
•Determine the TOTAL STROKE LENGTH the drill must travel to perform the drilling operation.
•Loosen cap screw (28) securing yoke assembly (27) to quill
(55)and position yoke assembly on quill approximately 5/8” (16 mm) greater distance between control valve (39) and yoke assembly than the distance of the Total Stroke Length.
•Tighten cap screw (28), securing yoke assembly (27) to quill
•Loosen nut (29), securing cap screw (30) and turn cap screw
(30)so the distance between the head of the cap screw (30) and control valve (39) equals the total stroke length.
•Tighten nut (29), securing cap screw (30).
•Replace cover (33), securing with screw (41).
•Attach air supply to tool.
FEED RATE CONTROL VALVES
•Turn valve (103), marked ‘‘R” at side of control assembly (93), approximately
•Turn the other valve (103), marked ‘‘F” at side of control as- sembly (93), clockwise until closed (do not tighten too snugly).
•Start the unit and slowly turn valve (103) marked ‘‘F” counter– clockwise (open) until the desired forward rate of feed is reached.
•A final adjustment of the rate of return (retract) can be made with the valve (103) marked ‘‘R”.
DISASSEMBLY/ASSEMBLY INSTRUCTIONS
•Disconnect air and electrical supply ‘‘BEFORE” performing maintenance or service to tool.
•Never apply excessive pressure by a holding device which may cause distortion of a part.
•Apply pressure evenly to parts which have a press fit.
•Apply even pressure to the bearing race that will be press fitted to the mating part.
•Use correct tools and fixtures when servicing this tool.
•Don’t damage ‘‘O” rings when servicing this tool.
•Use only genuine ARO replacement parts for this tool. When ordering, specify part number, description, tool model number and serial number.
BELT AND PULLEY SECTION DISASSEMBLY
_ Remove four screws (1), releasing cover (2).
_ Loosen cap screw (13), loosening tensioner assembly. _ Remove belt (3).
_ Remove cap screws (4) and washers (5), releasing pulleys (7 and 12) and keys (6).
_ To remove motor (11), remove four cap screws (9).
_ Remove cap screw (13), releasing tensioner assembly.
_ To disassemble, remove retaining ring (14), releasing spring washer (15), bearings (16) and tension wheel (17).
BELT AND PULLEY SECTION ASSEMBLY
_ Apply thread adhesive (Loctite 242) to threads of tension wheel pin (18) and assemble to bracket (19).
_ Assemble bearing (16), tension wheel (17) and bearing (16) to tension wheel pin (18), securing with spring washer (15) and retaining ring (14).
_ Assemble tensioner assembly to housing (10), securing with cap screw (13). Do not tighten cap screw.
_ Assemble motor (11) to housing (10), securing with four cap screws (9).
_ Assemble keys (6) and pulleys (7 and 12) to spindle (23) and motor spindle.
_ Apply thread adhesive (Loctite 290) to threads of cap screws
(4)and assemble screws and washers (5) to spindles, secur- ing pulleys. NOTE: Tighten screws (4) to 50 – 60 in. lbs.
_ Assemble belt (3) over pulleys (7 and 12) and inside belt ten- sioner.
_ Hold tensioner assembly firmly against belt (3) and secure by tightening cap screw (13).
_ Assemble cover (2) to housing, securing with four screws (1).
PULLEY SPINDLE SECTION DISASSEMBLY
_ Follow instructions for disassembly of BELT AND PULLEY SECTION and remove belt (3) and pulley (12).
_ Remove four cap screws (20) and separate drive housing (10) from frame assembly (35). NOTE: Housings will have to be pulled apart approximately 11” (279 mm) to completely sepa- rate pulley spindle (23) from frame assembly (35).
_ Using a spanner type wrench, unthread and remove lock screw (25).
_ Pull spindle (23) and components from housing (10).
_ NOTE: Bearings (21) are press fit on spindle (23). Do not re- move unless it should become necessary to replace, as Brin- elling of the bearing races may occur, making replacement necessary.
3