Page 5 of 8PH10A-XXX-XXX(en)
PARTSLIST / PH10A -XXX-XXX FLUID SECTION.TORQUE REQUIREMENTS ,
NOTE:DO NOT OVERTIGHTEN FASTENERS.
(14)Bolt, 49 - 52 ft lbs (66.4 - 70.5 Nm).
(26)Bolts, 120 - 140 in. lbs (13.6 - 15.8 Nm).
(29)Flange nuts, 280 - 300 in. lbs (31.6 - 33.9 Nm) tighten alternately and evenly.
LUBRICATION/ SEALANTS
jApplyKey-Lube grease (93706-1) to all āOā rings, āUā cups and mating parts.
kApplyLoctite 572tto threads at assembly.
lApplyLoctite 271 to threads at assembly.
mApplyanti-sieze compound to threads and bolt and nut flange heads which
contactpump case when using stainless steel fasteners.
ASSEMBLYNOTES
nAssemblewith i.d. chamfer against bolt head.
oAssemblewith largest convolusion (ripple) towards (6) diaphragm plate. Figure2
FORTHE AIR MOTOR SECTION
SEEPAGES 6 & 7
36
26,m
2j1
124
149
150j148 151
153j
152
153j
154
164 165j
163
3j5
63j
7o
9n14,l
m.29
32
67
43
19j
21
22
15
1
8
6
42
3
7
5
TorqueSequence
125
155
159j
158m
125
j159
k126
Largestconvolusion (ripple) this side.