INTEC | 1206 |
SECTION 4
Filter Element Servicing (cont.)
4.3.2Inspection – Normal conditions.
At each 150 hours of operation or upon activation of the low inlet pressure warning light, Remove the elements and inspect in accordance with paragraphs 4.3.1a, b, c and d. Elements should be replaced after 1500 hours in service.
4.4Oiling The Filter Element
CAUTION: Use only Oil, PN 40 – 10 or PN
AeroFilter oil is a compounded mineral based blend, formulated with special polymers to form the tack barrier. A dye has been added to show where the oil has been applied. Eventually the red color will fade but the oil will remain.
CAUTION: Never use the filter element without AeroFilter oil.
DO NOT use Engine Oil
DO NOT use Transmission Oil
DO NOT use Hydraulic Fluid
DO NOT use Lightweight Oils (WD 40, LPS, etc)
a)Fill sprayer with recommended quantity of Aerofilter oil (8 Fluid Ounces).
b)Charge sprayer with compressed air.
c)Apply oil to the filter element with smooth, complete passes parallel to pleats.
d)Repeat 90 degrees to pleats.
e)Use all of the measured quantity of oil.
f)Wait 30 minutes for proper wicking and lightly
NOTE
Do not
The filter element is now ready for installation. Ref. Par. 4.2.
REVISION: B – 05/12/03 | 10 of 10 |