Intec STC SR00180SE Inspection/Test Requirements, Service/Inspection/Test Intervals, Section

Models: STC SR00180SE

1 10
Download 10 pages 19.98 Kb
Page 7
Image 7

INTEC

1206 SERIES-ICA-1

SECTION 3

Inspection/Test Requirements

3.1General

This section covers the basic maintenance and service requirements necessary for safe operation and continued airworthiness of the Model 1206 and 1407 Engine Filter Systems. The service and inspection intervals designated herein are the maximum allowable and should not be exceeded.

3.2Service Intervals

When severe or unusual environmental conditions exist or as flight requirements dictate, it is the responsibility of the operator to increase the frequency and scope of inspections necessary to ensure safe operation. Due to the operational nature of a "barrier" type filter, an important criteria for safe and successful operation is an unobstructed inlet/filter system. This can be accomplished by visual inspection of the filter through the inlet fairing prior to each flight. Where as small suspended particles on the outside of the filter element do not cause an appreciable airflow restriction, large, obvious debris such as leaves, brush, litter, etc., should be removed prior to flight. Good judgment and practice will ensure safe operation as well as long filter life.

Inspections, scheduled and conditional, shall be performed by qualified personnel and in accordance with standard aircraft practice. Compliance with all applicable Service Bulletins and Airworthiness Directives is mandatory.

Refer to paragraphs 4.3.1 and 4.3.2 for post cleaning inspections.

Service/Inspection/Test Intervals

EACH FLIGHT

100 HOUR INTERVAL

300 HOUR INTERVAL

ANNUAL INTERVAL

ITEM

 

 

 

 

 

 

 

 

 

 

 

a

Visual inspection of filter element

(installed).

 

 

 

b

Inspect, clean and re-oil filter element.

 

*

 

 

 

* Ref. to 4.3.1 & 4.3.2 for additional cleaning interval information.

 

 

 

c

Inspect and cycle alternate air door.

 

 

d

Inspect differential pressure switch/ warning annunciator components.

 

 

e

Inspect electrical connections.

 

 

f

Inspect attachment hardware, mounting brackets, and inlet ring

 

 

g

Inspect filter housing structure and associated hardware for cracks

 

 

 

and general security.

 

 

 

 

h

Leak and pressure test differential pressure switch/annunciator

 

 

 

 

system.

 

 

 

 

REVISION: B – 05/12/03

7 of 10

Page 7
Image 7
Intec STC SR00180SE manual Inspection/Test Requirements, Service/Inspection/Test Intervals, Section