Global Call API for HMP on Windows Programming Guide — August 2006 121
Real Time Configuration Management
4. Call the gc_GetConfigData( ) or gc_SetConfigData( ) function with:
target_type = GCTGT_CCLIB_SYSTEM
target_id = CCLib ID
time_out = 0
mode = EV_SYNC
5. If the gc_GetConfigData( ) function returns successfully, then obtain the individual parameter
data by calling the gc_util_get_next_parm() function. If an error occurs, call the
gc_ErrorInfo() function to find the error and correct it.
9.7.3 Getting or Setting Line Device Configuration in Synchronous Mode
Note: This section applies to E1, T1 and ISDN technologies only.
The Global Call RTCM feature also allows the customer application to retrieve or change the
default configuration of a line device in synchronous mode. Synchronous mode can be used
effectively in any of the following cases:
The request is to retrieve parameters.
The request is to update parameters that are NOT call related.
The request is to update parameters that are call related but there is no active call on the target
object.
The target type is neither GCTGT_FIRMWARE_CHAN nor GCTGT_FIRMWARE_NETIF
(that is, the parameters are not maintained in the firmware).
Figure29 shows the procedure for getting or setting line device configuration in synchronous
mode.