Table 3. SATA Connector to SFF8087 Connector
Controller Connector | Expander Connector | |||
|
| |||
|
|
| ||
|
|
|
|
|
Pin No |
| Signal | Pin No | Signal |
|
|
|
|
|
P0_1 |
| GND | A1 | GND |
|
|
|
|
|
P0_2 |
| TX+ | A2 | SAS_RX_C_DP<3> |
|
|
|
|
|
P0_3 |
| TX+ | A3 | SAS_RX_C_DN<3> |
|
|
|
|
|
P0_4 |
| GND | A4 | GND |
|
|
|
|
|
|
|
| B4 | GND |
|
|
|
|
|
P0_5 |
| RX- | B3 | SAS_TX_C_DN<3> |
|
|
|
|
|
P0_6 |
| RX+ | B2 | SAS_TX_C_DP<3> |
|
|
|
|
|
P0_7 |
| GND | B1 | GND |
|
|
|
|
|
P1_1 |
| GND | A4 | GND |
|
|
|
|
|
P1_2 |
| TX+ | A5 | SAS_RX_C_DP<2> |
|
|
|
|
|
P1_3 |
| TX+ | A6 | SAS_RX_C_DN<2> |
|
|
|
|
|
P1_4 |
| GND | A7 | GND |
|
|
|
|
|
|
|
| B7 | GND |
|
|
|
|
|
P1_5 |
| RX- | B6 | SAS_TX_C_DN<2> |
|
|
|
|
|
P1_6 |
| RX+ | B5 | SAS_TX_C_DP<2> |
|
|
|
|
|
P1_7 |
| GND | B4 | GND |
|
|
|
|
|
7 |
| NC | A8 | SAS_A_SB_BP_TYPE |
|
|
|
|
|
5 |
| NC | A9 | GND |
|
|
|
|
|
3 |
| NC | A10 | SAS_A_SB4 |
|
|
|
|
|
1 |
| NC | A11 | SAS_A_SB5 |
|
|
|
|
|
8 |
| NC | B8 | SAS_A_SB0 |
|
|
|
|
|
6 |
| NC | B9 | SAS_A_SB1 |
|
|
|
|
|
4 |
| NC | B10 | GND |
|
|
|
|
|
2 |
| NC | B11 | SAS_A_SB_CTRL_TYPE |
|
|
|
|
|
P2_1 |
| GND | A12 | GND |
|
|
|
|
|
P2_2 |
| TX+ | A13 | SAS_RX_C_DP<1> |
|
|
|
|
|
P2_3 |
| TX+ | A14 | SAS_RX_C_DN<1> |
|
|
|
|
|
P2_4 |
| GND | A15 | GND |
|
|
|
|
|
18 | Intel® RAID Expander Card RES2SV240 Hardware User’s Guide |