StorTrends® iTX Installation and Login Intel® Server System SSR212MC2
Step
6
Description
The StorTrends iTX installation begins, but before it proceeds, it will prompt with a message depending on how many notebook hard disk drives are installed. The Intel® Server System SSR212MC2 has a dedicated bay for up to two notebook hard disk drives used to hold the operating system.
If there is only one notebook hard disk drive installed, the system will prompt with a message stating, “Warning!!! Detected a single OS disk for the
StorTrends iTX installation. Any OS disk failure will result in the system becoming unusable. Choose “YES” to continue, “NO” to exit from the installation.”
Welcome to StorTrends iTX 2.7
OS Array Configuration
Warning!!! Detected a single OS disk for the StorTrends iTX installation. Any OS disk failure will result in the system becoming unusable. Choose YES to continue,
NO to exit from the installation.
|
|
|
|
|
|
|
|
| YES |
|
|
|
| NO |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
<Enter> to reboot
If two notebook hard disk drives are installed, StorTrends iTX will automatically detect them and will mirror the installation of itself over both hard disk drives. Prior to beginning the installation, the system will prompt with the following message, “Detected multiple disks. The OS will be installed on a RAID 1
array.”
Welcome to StorTrends iTX 2.7
OS Array Configuration
Detected multiple disks. The OS will be installed on a RAID 1 array.
OK
<Enter> to reboot
Note: It is recommended that two notebook hard disk drives are present in the
14