SET-UP INSTRUCTIONS

(58) MODEL 604 FILTER PUMP ENGLISH 7.5” X 10.5” PANTONE 295U 01/19/2007

58

SET-UP INSTRUCTIONS

Be sure you have access to water to fill the pool and chemicals for the water. A small coin can be used to tighten the hose clamps (8).

IMPORTANT: This filter pump is shipped with the air release valve (1) open (open the air release valve if necessary). DO NOT replace the air release valve until you reach STEP #8. Failure to follow these instructions will result in air trapped inside filter housing; the motor will run dry, be noisy and malfunction.

1.Assemble above-ground-pool first. Carefully follow the pool’s installation instructions.

2.Place the Filter-Pump the length of the hose away from the pool wall where the lower black protruding hose connection is "sticking-out".

3.Remove wall plugs and then insert the strainers (6) into each of the protruding hose connections. The hoses (7) fit over the strainers inserted into the connections.

4.There are two hoses to be connected to the Filter-Pump hose connections. With hose clamps (8), fasten one of the hoses (7) to the lower protruding hose connection (marked "+" on the pool liner) and to the pump connection (marked "+").

5.Connect the second hose to the remaining upper protruding hose connection and to the lower pump connection. Make sure all the hose clamps (8) are tight.

6.Twist the Filter-Pump’s threaded cover (3) in a clock-wise direction to be sure it is on "tight". Use only your hands to tighten the top. Do not tighten with tools such as pliers.

7.Fill the pool to a level of at least 1-2 inches above the top connection. The water will automatically flow down into the pump.

8.When water starts flowing out of the air release valve hole, screw in the air release valve back into the filter housing cover. Do not over tighten the valve.

NOTE: Venting the system is necessary for air to escape as the filter housing fills with water.

9.Connect the filter pump to the power outlet. The filter pump is now filtering the water.

WARNING

Risk of electric shock. Connect this product only to a grounding type receptacle protected by a ground-fault circuit interrupter (GFCI) or residual current device (RCD). Contact a qualified electrician if you cannot verify that the receptacle is protected by a GFCI/RCD. Use a qualified electrician to install the GFCI/RCD, which has a maximum rate of 30mA. Do not use a portable residual current device (PRCD).

10.Operate the filter pump until the desired water clarity is obtained.

SAVE THESE INSTRUCTIONS