FLOW CHARTISPLAYCOLOR SETUP (examples)Example 1:Output 1 & Output 2: SSRAlarm setup: Absolute, Above, Alarm 2 HI Value "ALR.H" =200, Alarm 1 HI Value "ALR.H"=400Color Display setup: Normal Color "N.CLR"=Green, Alarm 1Color "1.CLR"=Amber, Alarm 2 Color "2.CLR"=RedDisplay colors change sequences:GREEN | RED | AMBER------------------------------------------------------------------------0 AL2.H=200 AL1.H=400 Example 2:Output 1: Relay, Set Point 1 = 200,Output 2: Relay, Set Point 2 = 200Alarm 1 setup: Deviation, Band, "ALR.H" = 20 Alarm 2 setup: Deviation, Hi/Low, "ALR.H = 10", "ALR.L = 5"Color Display setup: "N.CLR"=Green, "1.CLR"=Amber,"2.CLR"=RedDisplay colors change sequences:AMBER | RED | GREEN | GREEN |RED | AMBER---------------------------------------------------------------------0 180 195 200 210 220 READING CONFIGURATION SETUP(operation example)Below is a flowchart showing how to navigate through thesubmenus of the Reading Configuration menu item bypressing the front buttons.
Where:
CALC/VALUE = Calculated input based onthe transducer specification[WithoutKnown Loads (DSBL)]ACT/VALUE = Actual signal being received[Known Loads (ENBL)]
MQS3536/1204SPECIFICATIONAccuracy:0.03% rdg.Resolution:10 / 1 µVprocessLinearization Points:10 pointsTemperature Stability:50 ppm/°C processDisplay:4-digit, 9-segment LED, 10.2 mm (0.40") with red, green andamber programmable colorsInput Types:Analog Voltage and CurrentVoltage:0 to 100 mV, 0 to 1 V (+100 mV),0 to 10 VdcInput Impedance: 10 MΩ for 100 mV1 MΩ for 1 or 10 VdcCurrent:0 to 20 mA(5 Ω load)Output 1:Relay 250 Vac @ 3 AResistive Load,SSR, Pulse, Analog Voltage and CurrentOutput 2:Relay 250 Vac @ 3 AResistive Load,SSR, PulseOptions:CommunicationRS-232 / RS-485 orExcitation:5 Vdc@ 40 mA, 10 Vdc @ 60 mA
Exc. not available for Low Power Option
Line Voltage/Power:90 - 240 Vac ±10%,50 - 400 Hz*, or110 - 375 Vdc, 4 W
* No CE compliance above 60 Hz
Low Voltage Power Option:12 - 36 Vdc, 3 W**
**Units can be powered safely with 24 Vac
but No Certification for CE/ULare claimed.
Dimensions:25.4 H x 48 W x 126.3 D mm (1.0 x 1.89 x 5")Weight:127 g (0.28 lb)Approvals:UL, C-UL, CE per EN61010-1:2001
d dbb
• • •
ddb
dbb
d dbb
• • •
dbd
ddd
bc d
ddd
dddd
• • • • • • • •
a
a
a
bc
bcbc
bcbc
WARRANTY/DISCLAIMER
OMEGAENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of
one(1) year from the date of purchase. In addition to OMEGA’s standard warranty period, OMEGA Engineering will
extend the warranty period for four (4) additional years if the warranty card enclosed with each instrument is
returned to OMEGA.
If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will
issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA,
if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTYdoes not apply
to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing,
operation outside of design limits, improper repair, or unauthorized modification. This WARRANTYis VOID if the unit
shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive
corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating
conditions outside of OMEGA’s control. Components which wear are not warranted, including but not limited to
contact points, fuses, and triacs.
OMEGAis pleased to offer suggestions on the use of its various products. However, OMEGA neither
assumes responsibility for any omissions or errors nor assumes liability for any damages that result from
the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA
warrants only that the parts manufactured by it will be as specified and free of defects. OMEGA MAKES NO
OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED,
EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF
MERCHANTABILITYAND FITNESS FOR APARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION
OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGAwith
respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or
otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event
shall OMEGAbe liable for consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGAis not intended to be used, nor shall it be used: (1) as a “Basic
Component” under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications
or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application,
used on humans, or misused in any way, OMEGAassumes no responsibility as set forth in our basic
WARRANTY/DISCLAIMER language, and, additionally, purchaser will indemnify OMEGAand hold OMEGAharmless
from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGACustomer Service Department. BEFORE
RETURNING ANYPRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR)
NUMBER FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING
DELAYS). The assigned AR number should then be marked on the outside of the return package and on any
correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in
transit.
FOR WARRANTYRETURNS, please have the
following information available BEFORE
contacting OMEGA:
1. Purchase Order number under which the product
was PURCHASED,
2. Model and serial number of the product under
warranty, and
3. Repair instructions and/or specific problems
relative to the product.
FOR NON-WARRANTYREPAIRS, consult OMEGA for
current repair charges. Have the following information
available BEFORE contacting OMEGA:
1. Purchase Order number to cover the COST of the
repair,
2. Model and serial number of product, and
3. Repair instructions and/or specific problems
relative to the product.
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords
our customers the latest in technology and engineering.
OMEGAis a registered trademark of OMEGAENGINEERING, INC.
© Copyright 2004 OMEGAENGINEERING, INC. All rights reserved. This document may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without
the prior written consent of OMEGAENGINEERING, INC.
PATENTAND TRADEMARK NOTICE: This product is covered by one or more of the following patents: U.S. Pat.
No. Des. 336,895; 5,274,577; 6,243,021 / CANADA2052599; 2052600 / ITALY 1249456; 1250938 / GERMANY DE
41 34398 C2 / SPAIN 2039150; 2048066 / UK Patent No. GB2 249 837; GB2 248 954 / FRANCE BREVET NO. 91
12756. The “Meter Bezel Design” is a trademark of Newport Electronics, Inc. USED UNDER LICENSE. Other U.S.
and International Patents pending or applied for.
This device is marked with the international caution symbol. It is important to read theSetupGuide before installing or commissioning this device, as the guide contains importantinformation relating to safety and EMC.WARNING: These products are not designed for use in, and should not be used for, patient-connected applications.It is the policy of OMEGAto comply with all worldwide safety and EMC/EMI regulations that apply.OEMGAis constantly pursuing certification of its products to the European New Approach Directives.OMEGAwill add the CE mark to every appropriate device upon certification.The information contained in this document is believed to be correct, but OMEGAEngineering, Inc.accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.TRADEMARK NOTICE:
®,omega.com®,, and ®are Trademarks of
OMEGAENGINEERING, INC.
®

USA

MADE IN

CNiS32

Process / Strain Gauge

Controller

Servicing North America:USA: One Omega Drive, P.O. Box 4047ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.comCanada: 976 Bergar Laval (Quebec) H7L 5A1 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.caFor immediate technical or application assistance:USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA®
Customer Service: 1-800-622-2378 / 1-800-622-BEST®
Engineering Service: 1-800-872-9436 / 1-800-USA-WHEN®
Mexico and TEL: (001)800-TC-OMEGA® FAX: (001) 203-359-7807 Latin American: En Español: (001) 203-359-7803 e-mail: espanol@omega.comServicing Europe:Benelux: Postbus 8034, 1180 LA Amstelveen, The Netherlands TEL: +31 20 3472121 FAX: +31 20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: sales@omegaeng.nlCzech Republic: Frystatska 184, 733 01 Karviná TEL: +420 59 6311899 FAX: +420 59 6311114 e-mail: info@omegashop.czFrance: 11, rue Jacques Cartier, 78280 Guyancourt TEL: +33 1 61 37 29 00 FAX: +33 1 30 57 54 27 Toll Free in France: 0800 466 342 e-mail: sales@omega.frGermany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany TEL: +49 7056 9398-0 FAX: +49 7056 9398-29 Toll Free in Germany: 0800 639 7678 e-mail: info@omega.deUnited Kingdom: One Omega DriveISO 9002 Certified River Bend Technology Centre Northbank, Irlam Manchester M44 5BD United Kingdom TEL: +44 161 777 6611 FAX: +44 161 777 6622 Toll Free in England: 0800 488 488 e-mail: sales@omega.co.ukOMEGAnet® On-Line Servicewww.omega.comInternet e-mailinfo@omega.com®
®