© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Washer-Extractors
10
5-08-53
Installation - Models IHF033, IHF045 and IHF055
Ground
The machine must be placed on a flat, solid surface
(metal base, concrete or solid ground). It is
recommended that the machine be anchored on the
provided places (1) in the base, especially in case of a
plinth. Refer to Figure6.
Figure 6
The machine must be placed entirely level. For easy
maintenance it is recommended to keep a minimal
distance of 23.62 in. (600 mm) between the wall and
the back of the machine.
If several machines are placed next to each other, there
should be a minimal distance of 1.18 in. (30 mm)
between each machine.
Electrical Installation Requirements - Models IHF033, IHF045 and IHF055
Table 1
CHM2180N
1Mounting Bolt Holes
1
Machine with steam heating or boiler fed
machines without additional electrical heating
220V 3AC 380V 3AC + N
16 A 16 A
Machine with electrical heating
220V 3AC 380V 3AC + N
9 kW 25 A 16 A
12 kW 40 A 20 A
15 kW 50 A 25 A
18 kW 50 A 32 A
21 kW N/A 40 A
24 kW N/A 40 A