© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Washer-Extractors
5-08-53
21
Installation - Models IHF100 and IHF135
Ground
The machine must be placed on a flat, solid surface
(metal base, concrete or solid ground). It is
recommended that the machine be anchored (M16) on
the provided places (1) in the base, especially in case
of a plinth. Refer to Figure14.
Figure 14
The machine must be placed entirely level. For easy
maintenance it is recommended to keep a minimal
distance of 23.62 in. (600 mm) between the wall and
the back of the machine.
If several machines are placed next to each other, there
should be a minimal distance of 1.18 in. (30 mm)
between each machine.
Electrical Installation Requirements - Models IHF100 and IHF135
Table 3
CHM2180N
1Mounting Bolt Holes
1
Machine without electrical heating
220V 3AC 380V 3AC + N
20 A 20 A
Machine with electrical heating
220V 3AC 380V 3AC + N
27 kW 80 A 63 A
36 kW N/A 80 A