GAS LINE
Remove the 3/8” flare fitting that attaches the propane hose from the Manifold block inside of the pedestal and replace with an approved 10’ Natural Gas Hose neoprene hose. Part # NGHOSE
REMEMBER TO LEAK CHECK ALL FITTINGS AND ORIFICES AFTER ALL OF THE CONVERSION IS COMPLETED, LEAK CHECK ALL FITTINGS AND TEST FIRE ALL BURNERS TO ENSURE PROPER, SAFE OPERATION.
Remove Propane hose and regulator assembly and Install new Natural gas Hose
MAINTENANCE
Burner Inspection: Please inspect these burners once a year.
Periodically inspect the burners for blockage or corrosion. These burners can be cleaned using a small piece of wire and a wire brush. Be careful not to damage the ceramic spark electrode. Have the burner replaced if there are any signs of deterioration.
BURNER REMOVAL FOR CLEANING
1.Ensure the gas supply is off and grill is cool.
2.Remove Cooking Grids and Upper Flavor Shields.
3.Remove the burner mounting screw located at the very back of burner near the rear of the firebox.
4.Remove burners by lifting up and out of firebox on an angle. Repeat for all burners.
5.Clean the outside of the burners with a Brass Bristle wire brush and make sure all gas ports are clear. Use a straight coat hanger to clear any obstructions.
6.Use a flashlight to look into the venturi end of the burner to check for blockages. If necessary, use a straight coat hanger to clear any obstructions.
7.Inspect and clean the venturi end of the burner by removing the venturi set screw on the end of the burner and removing the venturi shutter. Once removed, make sure the burner is thoroughly cleaned and the venturi shutter is
8.
9.
10.Light each burner to ensure they are operating correctly.
Note: When installing burners, it is very important to center the burner over the gas orifice. You should look under the main control panel with a flashlight once installed to make sure they are in the proper position. Failure to clean and install burners correctly could result in fire or explosion.