SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
ELECTRICAL INSTALLATION INSTRUCTIONS
ELECTRICAL POWER CONNECTION: Electrical and grounding connections must comply with all applicable portions of the National Electric Code (ANSI/NFPA 70) and/or other electrical codes that may apply.
Disconnect the electrical power supply and lockout the disconnect switch to indicate that you are working on the circuit.
The dishmachine data plate is located on the left front corner of the machine. Refer to this data plate for information concern- ing the unit’s specific electrical requirements.
To install the incoming power lines, open the connection box by removing the con- nection box lid. Install 1/2” conduit into the
It is recommended that
VOLTAGE CHECK: Ensure that the machine is off and apply power to the machine. Check the incoming power at the terminal block and ensure it corresponds to the voltage on the machine data plate. Do not run the dishmachine if the voltage is too high or too low. Shut off the service breaker and mark it as being for the dishma- chine. Advise all personnel of the location of the service breaker. Replace all covers and tighten the screws.
|
| Power Block |
Ground Lug |
NOTE: Always refer to the machine data plate for specific electrical and water requirements. The material provided on this page is for reference only and may be subject to change without notice.