Jackson Delta 5 Specification Information, Specifications Of The Delta, Operating Cycles Seconds

Models: DELTA 5 D Delta 5

1 52
Download 52 pages 45.53 Kb
Page 8
Image 8
SECTION 1: SPECIFICATION INFORMATION

SECTION 1: SPECIFICATION INFORMATION

SPECIFICATIONS OF THE DELTA 5

OPERATING CAPACITY ( NSF RATED):

 

RACKS PER HOUR

29

DISHES PER HOUR

725

GLASSES PER HOUR

725

OPERATING CYCLES (SECONDS):

 

NORMAL CYCLE:

 

WASH TIME

45

RINSE TIME

25

TOTAL CYCLE TIME

90

WASH TANK CAPACITY (GALLONS):

1.2

WASH PUMP CAPACITY (GPM):

61

OPERATING TEMPERATURES:

 

ELECTRICAL REQUIREMENTS:

 

 

WASH PUMP MOTOR HP

 

3/4

 

 

 

RINSE

 

TYPICAL

 

 

 

HEATER

TOTAL

ELECTRICAL

VOLTS

PH

HZ

RATINGS

AMPS

CIRCUIT

115

1

60

2KW@110V

*16 A

20 AMP

*This dishmachine is designed so that the wash motor is never running when the wash heater is on. Service load is based upon the higher of the two amperages.

NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service contractor that your circuit protection is adequate and meets all applicable national and local codes. These numbers are provided in this manual simply for reference and may change without notice at any given time.

FRAME DIMENSIONS:

WASH (MINIMUM)

(48.9°C) 120°F

WIDTH

(622.3mm)

24 1/2”

WASH (RECOMMENDED)

(60.0°C) 140°F

RINSE (MINIMUM)

(48.9°C) 120°F

DEPTH

(641.35mm)

25 1/4”

RINSE (RECOMMENDED)

(60.0°C) 140°F

DEPTH, WITH FRONT DOOR OPEN

(933.45mm)

36 3/4”

 

 

HEIGHT

(990.6mm)

39”

 

 

MAXIMUM WASH

 

 

WATER REQUIREMENTS:

 

CHAMBER CLEARANCE

(292.1mm)

11 1/2”

WATER LINE SIZE NPT

1/2”

FRAME DIMENSION (DOUBLE DOOR):

 

DRAIN LINE SIZE NPT

2”

WIDTH

(622.3MM)

24 1/2”

FLOW PRESSURE

20 ±5 PSI

DEPTH

(714.375MM)

28 1/8”

 

 

DEPTH, WITH DOOR OPEN

(1311.275MM)

51 5/8”

MINIMUM CHLORINE REQUIRED (PPM):

50

HEIGHT

(990.6MM)

39”

 

 

CHAMBER CLEARANCE

(292.1MM)

11 1/2”

 

 

NOTE: Always refer to the machine data plate for specific

electrical and water requirements. The material provided on this page is for reference only and may be subject to change without notice.

Delta 5 Installation & Operation Manual 7610-003-37-08

Issued: 05-25-2007 Revised: N/A

2

Page 8
Image 8
Jackson Delta 5 Specification Information, Specifications Of The Delta, Operating Capacity Nsf Rated, Wash Pump Motor Hp