Jackson JPX-300NSU technical manual After Maintenance Actions

Models: JPX-300NSU

1 47
Download 47 pages 11.95 Kb
Page 25
Image 25

SECTION 5: SERVICE PROCEDURES

RINSE SOLENOID VALVE REPAIR PARTS KIT (CONTINUED)

Removing the screen retainer

19.Using the small flathead screwdriver, lift out the screen retainer. Verify that the holes in it are free of clogs and debris.

21.With the mesh screen removed, look down into the valve and verify it is not clogged. Remove any foreign objects from the valve body that would obstruct flow.

22.Reassemble the valve, reversing the steps needed to take it apart. Replace defective replacement parts with new parts from ordered kits. Ensure that components are sufficiently tightened to prevent leakage.

AFTER MAINTENANCE ACTIONS

Reconnect the incoming water (if disconnected) and turn on. Then restore power to the unit. Run the unit for at least 10 minutes to ensure there are no leaks. If any problems arise please contact Jackson.

Removing the mesh strainer screen

20.Again using the small flathead screwdriver, carefully remove the mesh screen from inside the valve body. The screen should be taken and rinsed out to remove any debris fouling it.

SPECIAL PARTS

Solenoid Valve Plunger Kit

Includes plunger and spring

Part number 6401-003-07-40

Solenoid Valve Diaphragm Kit Includes diaphragm and o-ring

Part number 6401-003-07-41 (1/2” NPT)

Solenoid Valve 110 Volt Coil and Housing Kit Part number 6401-003-07-43

Complete Solenoid Valve

Part number 04810-100-12-18 (1/2”, 110 Volt)

View inside the solenoid valve body

JPX-300NSU Technical Manual

7610-002-75-96 Rev. E (08/16/2005))