2-82Operation, administration, and maintenance (OAM) features

Table 2-12 (continued)

Egress WAN port and service alarms

Alarm

Description

Severity

 

 

 

Link Down

This alarm is raised against the WAN port

Critical, service affecting (C, SA)

(See Note)

when the administrative state of the WAN

 

 

port on a 2xGigE/FC-P2P circuit pack is

 

 

up but the operating state of the port is

 

 

down.

 

 

 

 

Rx Signal Degrade

This alarm is raised against the WAN port

Minor, service affecting (mn,SA)

 

when the following occurs:

 

 

• For GFP-F, this alarm is raised when at

 

 

least 1 percent of the received frames

 

 

are errored per second, for 3

 

 

consecutive seconds.

 

 

• For GFP-T, this alarm is raised when at

 

 

least 1 percent of the received

 

 

superblocks are errored per second, for

 

 

3 consecutive seconds.

 

 

 

 

Rx Excessive Error ratio

This alarm is raised against the WAN port

Major, service affecting (Mj,SA)

 

when one of the following conditions

 

 

occurs:

 

 

• For GFP-F, this alarm is raised when at

 

 

least 20 percent of the received frames

 

 

are errored per second, for 3

 

 

consecutive seconds.

 

 

• For GFP-T, this alarm is raised when at

 

 

least 20 percent of the received

 

 

superblocks are errored per second, for

 

 

3 consecutive seconds.

 

 

 

 

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Page 120
Image 120
Nortel Networks NTRN10AN, 3500 manual 82Operation, administration, and maintenance OAM features