3-92Hardware feature descriptions

For information about Optical Ethernet Private Line service, see Optical Ethernet-Private Line (OE-PL) services using 10/100 Ethernet on page 2-66

For information about Ethernet Operational Measurements, see Ethernet Operational Measurements on page 2-70.

Equipping rules

Each 2x100BT-P2P circuit pack requires an 8xRJ-45 Front I/O module (NTN452NA) on the OPTera Metro 3500 Shelf (NTN476AA, NTN476DA). On the OPTera Metro 3500 Universal Shelf (NTN476AH) you must use the 8xRJ-45 Front Enhanced I/O module (NTN452NH) or the 8xRJ-45 Rear I/O module (NTN452HB).

Both versions of the shelf support eight 2x100BT-P2P circuit packs in slots 3 through 10. 2x100BT-P2P circuit packs only operate in an unprotected mode. Users can install only 2x100BT-P2P, 4x100BT, 4x100FX, and 2xGigE/FC-P2P circuit packs in adjacent slots. Only ports 1 and 2 of the I/O module will be used by the 2x100BT-P2P circuit pack. The remaining ports remain unused.

If a 2x100BT-P2P, 4x100FX, 4x100BT or 2xGigE/FC-P2P circuit pack is inserted into an odd slot (nodd), then you can only insert one of the following circuit packs into the even slot (nodd+1):

2x100BT-P2P

4x100BT

4x100FX

2xGigE/FC-P2P

If a 2x100BT-P2P, 4x100FX, 4x100BT or 2xGigE/FC-P2P circuit pack is

inserted into an even slot (neven), then you can only insert one of the following circuit packs into the odd slot (neven-1):

2x100BT-P2P

4x100BT

4x100FX

2xGigE/FC-P2P

Note: There is no equipment protection for the 2x100BT-P2P circuit pack.

See Table 3-3 on page 3-6for operational temperature ranges.

Note 1: If there is a 1-28 DS1 I/O module installed, and if slots 5 and 6 are not equipped with DS1 mappers, you may not install 2x100BT-P2P circuit packs in slots 5 or 6 (there is not enough room for slot 5 or slot 6’s 8xRJ-45 I/O modules).

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004