3-112Hardware feature descriptions

For more information, refer to:

DSM DS1x84 interface specifications on page 4-33in Part 2 of this guide

OC-3x4 optical interface specifications on page 4-10in Part 2 of this guide

Note 1: The NTN313AC circuit pack comes with LC connectors pre-installed.

Note 2: If you are ordering the NTN313AA circuit pack, you must also order the required optical connector kit (see Optical connector kits on page 8-18).

See Table 3-3 on page 3-6for operational temperature ranges.

Protection switching

DSM DS1x84 termination module protection switching is 1+1 non-revertive. If a working DSM DS1x84 TM becomes defective, the traffic is switched to the protection DSM DS1x84 TM. Switching can also take place under user control.

Alarm LED definitions

The following table provides a list of LEDs of the DSM DS1x84 TM.

LED Name

LED Color

ON condition description

 

 

 

Status

Status Red

Circuit pack is failed

 

 

 

Active

Active Green

Circuit pack is IS and ACT, OC3 facility and at

 

 

least one DS1 facility are IS or OOS-AU and cross

 

 

connected.

 

 

 

LOS

LOS Yellow

Loss of Signal on the OC3 facility.

 

 

 

Sync Ref Fail

Yellow

Loss of synchronization reference signal (own

 

 

line).

 

 

 

OAM fail

Yellow

OAM link to SPx failed.

 

 

 

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Page 340
Image 340
Nortel Networks NTRN10AN, 3500 manual LED Name LED Color On condition description, Los