Operation, administration, and maintenance (OAM) features 2-157

Synchronization-status messages are carried in bits 5 through 8 of the S1 byte in the SONET line overhead and in the extended superframe (ESF) datalink of the external DS1 signal from a BITS or a tributary. As the timing is passed from one network element to the next, each network element sends SSMs. If the quality of the timing changes, the SSMs inform the next network element of the change. See Table 2-33.

Table 2-33

Synchronization status messages and quality levels

Description

Quality

SONET S1 byte

Designation

ESF datalink

 

level

(bit 5 to bit 8)

 

code byte

 

 

 

 

 

Stratum 1—Traceable

1

0001

ST1 (PRS)

000010

 

 

 

 

 

Synchronized—

2

0000

STU

000100

Traceability unknown

 

 

 

 

 

 

 

 

 

Stratum 2—Traceable

3

0111

ST2

000110

 

 

 

 

 

Stratum 3—Traceable

4

1010

ST3

001000

 

 

 

 

 

SONET minimum

5

1100

SMC

010001

clock—Traceable

 

 

 

 

 

 

 

 

 

Stratum 4—Traceable

6

n/a

ST4

010100

(see Note 1)

 

 

 

 

 

 

 

 

 

Do not use for

8

1111

DUS

011000

synchronization

 

 

 

 

 

 

 

 

 

Reserved for network

7

1110

RES

100000

synchronization use

 

 

 

 

(holdover)

 

 

 

 

 

 

 

 

 

Note 1: The ST4 message is carried in the ESF datalink of an external DS1 timing signal, not in the SONET overhead.

Note 2: Any unsupported synchronization status message S1 or DS1 ESF datalink is byte-mapped to a DUS designation.

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004