Operation, administration, and maintenance (OAM) features 2-85

Virtual concatenation

When the VCAT attribute in the WAN port is set to ENABLE, up to 7 STS3c or 21 STS1 connections can be cross connected to a 2xGigE/FC-P2P WAN port.

STS-1-nv, n = 1 through 21 or,

STS-3c-nv, n = 1 through 7

Engineering rules

The following engineering rules apply to the bandwidth management capabilities of the 2xGigE/FC-P2P circuit packs:

When the VCAT attribute of the WAN port 1 and port 2 is set to DISABLE, if a STS1 granularity connection is made against one of these ports, the only valid connection that can be made against the other WAN port is STS1 connections.

When the VCAT attribute of the WAN port 1 and port 2 is set to DISABLE, if an STS-nc (STS3c, STS12c or STS24c) connection is made against one of these ports, the only valid connection that can be made against the other WAN port is STS-nc connections.

When the VCAT attribute of WAN port 1 and port 2 is set to ENABLE, both ports must have the same RATE attribute.

Facility attributes

The 2xGigE/FC-P2P circuit pack supports Ethernet, FC and WAN facilities.

Ethernet facility

Table 2-13 on page 2-85, lists facility parameters supported by the 2xGigE/FC-P2P Ethernet port.

Table 2-13

2xGigE/FC-P2P Ethernet port facility signal attributes

Signal Attribute

Definition

Values

Access

 

 

(See Note 1)

(see Note 2)

 

 

 

 

AN

Auto-Negotiation

Enable, Disable

R/W

(Auto-Negotiation)

 

 

 

 

 

 

 

ANSTATUS

Auto-Negotiation Status

InProgess, Completed,

R/O

(Auto-Negotiation

 

Disabled

 

Status)

 

 

 

 

 

 

 

ANETHDPX

Negotiated Duplex Operation, when AN is

Full

R/O

(Negotiated Duplex

enabled

 

 

Operation)

 

 

 

 

 

 

 

ANSPEED

Negotiated speed, when AN is enabled

1000

R/O

(Negotiated Speed)

 

 

 

 

 

 

 