2-104Operation, administration, and maintenance (OAM) features

See Table 2-22for a list of performance monitoring parameter definitions. For a list of DS3 performance monitoring parameters supported on the DS3 circuit packs, see Table 2-23. For a list of DS1 performance monitoring parameters supported on the DS1 and DS3VTx12 circuit packs, see Table 2-24.

Table 2-22

Performance monitoring parameter definitions

Parameters

 

Definitions

 

 

 

Section

 

 

 

 

 

CV-S

Coding violations,

• SONET: Count of BIP-8 errors (B1) byte

 

section

 

 

 

 

ES-S

Errored seconds,

• SONET: Count of one second intervals with

 

section

BIP-8 errors (B1) >=1 or LOF >=1 or LOS >=1

 

 

 

SES-S

Severely errored

• SONET: Count of one second intervals with

 

seconds, section

BIP=8 errors (B1) >=K (where K is 155 for OC-3,

 

 

616 for OC-12, 2392 for OC-48, 8854 for

 

 

OC-192) or SEF >=1 or LOS >=1

 

 

 

SEFS-S

Severely errored frame

• SONET: Count of one second intervals with any

 

seconds, section

LOF >=1

 

 

 

Line

 

 

 

 

 

CV-L

Coding violations, line

• SONET: Count of BIP-8 errors (B2 byte)

 

 

• DS1 / DS3x3 / DS3x12 / DS3x12e: Count of

 

 

BPV + EXZ BPVs which are part of the B3ZS

 

 

code are not counted, receive only

 

 

 

CV-LFE

Coding violations, line,

• SONET: Count of FEBE-L (Bits 2-8 of Z2 byte of

 

far-end

STS-1 No. 3)

 

 

 

ES-L

Errored seconds, line

• SONET: Count of one second intervals with

 

 

BIP-8 errors (B2) >=1 or AIS-L >=1

 

 

• DS1 / DS3: Count of one second intervals with

 

 

(BPV + EXZ) >=1 or LOS >=1, receive only

 

 

 

ES-LFE

Errored seconds, line,

• SONET: Count of one second intervals with

 

far-end

FEBE-L >=1 or RDI-L >=1

 

 

DS1-ESF: Count of one second PRM intervals

 

 

with LV=1 in the PRM, receive and transmit

 

 

 

SES-L

Severely errored

• SONET: Count of one second intervals with

 

seconds, line

BIP-8 errors (B2) >=K (where K is 154 for OC-3,

 

 

615 for OC-12, 2459 for OC48, 9835for

 

 

OC-192) or AIS-L >=1

 

 

• DS3: Count of one second intervals with (BPV +

 

 

EXZ) >=44 or LOS >=1, receive only

 

 

• DS1: Count of one second intervals with (BPV +

 

 

EXZ) >=1544 or LOS >=1, receive only

 

 

 