2-78Operation, administration, and maintenance (OAM) features

Table 2-11

Ingress LAN port alarms

Alarm

Description

Severity

 

 

 

Rx Loss of signal

This alarm is raised against the LAN port

Critical, service affecting (C,SA)

 

on a 2xGigE/FC-P2P circuit pack when

 

 

the circuit pack cannot detect an input

 

 

signal.

 

 

 

 

Rx Loss of data Sync

This alarm is raised against the LAN port

Critical, service affecting (C,SA)

(See Note 1)

of the 2xGigE/FC-P2P circuit pack when

 

 

one of the following conditions occurs:

 

 

• the circuit pack cannot establish bit

 

 

synchronization or transmission word

 

 

synchronization

 

 

• the Small Form Factor Pluggable (SFP)

 

 

optical transceiver module is the wrong

 

 

type (SX or LX)

 

 

• the client service provisioned on the

 

 

subtending transmit equipment does

 

 

not match the client service provisioned

 

 

on the 2xGigE/FC-P2P circuit pack

 

 

 

 

Link Down

This alarm is raised against the LAN

Critical, service affecting (C,SA)

 

Ethernet port when one of the following

 

 

conditions occurs:

 

 

auto-negotiation between the

 

 

2xGigE/FC-P2P circuit pack and the

 

 

local link partner does not complete

 

 

successfully

 

 

auto-negotiation is enabled on the

 

 

2xGigE/FC-P2P circuit pack but is

 

 

disabled on the local link partner

 

 

• the administrative state of the LAN port

 

 

on a 2xGigE/FC-P2P circuit pack is up

 

 

but the operating state of the port is

 

 

down

 

 

This alarm is raised against the LAN

 

 

Fibre Channel port when the Fibre

 

 

Channel link state is not active.

 

 

 

 

Rx Signal Degrade

This alarm is raised against the LAN port

Minor, service affecting (mn,SA)

 

when the following occurs:

 

 

• For Ethernet facilities, this alarm is

 

 

raised when at least 1 percent of the

 

 

received frames are errored per

 

 

second, for 3 consecutive seconds.

 

 

• For Fibre Channel facilities, this alarm

 

 

is raised when at least one symbol or

 

 

disparity error occurs per second, for 3

 

 

consecutive seconds.

 

 

 

 