Hardware feature descriptions 3-93

Note 2: If there is a 29-56 DS1 I/O module installed, and if slots 7 and 8 are not equipped with DS1 mappers, you may not install 2x100BT-P2P circuit packs in slots 7 and 8 (there is not enough room for slot 7 or slot 8’s 8xRJ-45 I/O modules).

Note 3: If there is a 29-84 DS1 I/O module installed, and if slots 7 through 10 are not equipped with DS1 mappers, you may not install 2x100BT-P2P circuit packs in slots 7 through 10 (there is not enough room for slot 7 through slot 10’s 8xRJ-45 I/O modules).

The following table describes the compatibility of each I/O module with both shelf types.

Shelf

I/O module

I/O scenario description

 

 

 

OPTera Metro 3500 Shelf

8xRJ-45 Front I/O module

front access to the I/O

Assembly (NTN476AA,

(NTN452NA)

 

NTN476DA)

 

 

 

 

 

OPTera Metro Universal

8xRJ-45 Front Enhanced

front access to the I/O,

Shelf Assembly

I/O module (NTN452NH)

extended temperature

(NTN476AH)

 

range

 

 

 

 

8xRJ-45 Rear I/O module

rear access to the I/O,

 

(NTN452HB)

extended temperature

 

 

range

 

 

 

Alarm LED definitions

The following table provides a list of the 2x100BT-P2P circuit pack LEDs. See Figure 3-28 on page 3-47for the 2x100BT-P2P circuit pack faceplate layout showing the location of the LEDs.

LED name

Color

Description

 

 

 

Status

red

Circuit pack failure

 

 

 

Active

green

The circuit pack is active. At least one Ethernet

 

 

facility is in service or at least one cross-connect

 

 

exists.

 

 

 

Link (1-2)

yellow

No link pulse is detected on Ethernet port and the

 

 

port is administratively up.

 

 

 

Planning and Ordering Guide—Part 1 of 2 NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Page 321