Nortel Networks NTRN10AN, 3500 manual Fc-Pfe

Models: 3500 NTRN10AN

1 342
Download 342 pages 27.69 Kb
Page 146
Image 146

2-108Operation, administration, and maintenance (OAM) features

Table 2-22 (continued)

Performance monitoring parameter definitions

Parameters

 

Definitions

 

 

 

FC-P

Failure count, path

• SONET: Count of near-end STS path failure

 

 

(LOP-P or AIS-P) events

 

 

• DS1: Count of near-end path failure (LOF or

 

 

AIS) events, receive and transmit

 

 

 

FC-PFE

Failure count, path,

• SONET: Count of far-end STS path failure

 

far-end

(RFI-P) events

 

 

• DS1: Count of far-end path failure (RAI) events,

 

 

receive and transmit

 

 

 

Note: The SESP parameter does not count frame errors for DS-1 facilities on DS-1 circuit packs.

Table 2-23

DS3 performance monitoring - supported parameters for DS3VTx12

PM parameter

DS3x3, DS3x12, DS3x12e

DS3VTx12 circuit pack

 

circuit packs

See Note

 

 

 

CVL Near End Rx

 

 

 

ESL Near End Rx

 

 

 

SESL Near End Rx

 

 

 

CVP Near End Rx

 

 

 

CVP Near End Tx

 

 

 

 

FCP Near End Rx

 

 

 

ESP Near End Rx

 

 

 

ESP Near End Tx

 

 

 

 

SESP Near End Rx

 

 

 

SESP Near End Tx

 

 

 

 

SASP Near End Rx

 

 

 

SASP Near End Tx

 

 

 

 

UASP Near End Rx

 

 

 

UASP Near End Tx

 

 

 

 

Note: DS3/VTx12 circuit pack is not supported on shelves equipped with STX-192 circuit packs.

OPTera Metro 3500 Multiservice Platform NTRN10AN Rel 12.1 Standard Iss 1 Apr 2004

Page 146
Image 146
Nortel Networks NTRN10AN, 3500 manual Fc-Pfe