3-74Hardware feature descriptions

OC-12 path switching uses nonrevertive protection. There are no permanent VT1.5, STS-1, STS-3c, or STS-12c protection or working paths. The network element receives two incoming VT1.5, STS-1, STS-3c, or STS-12c signals: one from the provisioned working optical interface circuit pack and one from the switchmate optical interface circuit pack. The network element selects the better of the two signals.

Note: VT1.5 signal rate is supported on OPTera Metro 3500 shelves equipped with VTX-series circuit packs.

Protection of path failures on a single OC-12 optical interface completes in 60 ms, but protection of simultaneous path failures on multiple OC-12 optical interfaces completes in less than 200 ms.

Section data communication channel (SDCC)

An OC-12 line carries a DCC channel that can be edited, provisioned, and deprovisioned.

Note 1: The maximum number of simultaneous SDCC-provisionable ports on an OPTera Metro 3500 shelf is 34 (the shelf must be equipped with eight unprotected OC-3x4 or OC-12x4 STS circuit packs in slots 3 through 10, and a protected pair of OC-48 or OC-192 circuit packs in slots 11 and 12).

Note 2: For Nortel Networks interworking and multi-vendor network scenarios, DCC interoperability can be achieved with the appropriate provisioning. See Optical Networks Data Communications Network Planning Guide, NTR710AM.

Alarm LED definitions

The following table provides a list of LEDS of the OC-12 interface circuit pack.

LED

Color

Description

 

 

 

Status (top)

Red

Circuit pack failure

 

 

 

 

Yellow

Loss of signal

 

 

 

Status (bottom)

Green

In service and carrying traffic

 

 

 