Jackson Tempstar Series technical manual Power Block

Models: Tempstar Series

1 103
Download 103 pages 7.57 Kb
Page 18
Image 18

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS (CONTINUED)

PLUMBING CHECK: Slowly turn on the water supply to the machine after the incoming fill line and the drain line have been installed. Check for any leaks and repair as required. All leaks must be repaired prior to placing the machine in operation.

ELECTRICAL POWER CONNECTION: Electrical and grounding connections must comply with the applicable portions of the National Electrical Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.

Disconnect electrical power supply and place a tag at the disconnect switch to indi- cate that you are working on the circuit.

The dishmachine data plate is located on the right side and to the front of the machine. Refer to the data plate for machine operating requirements, machine volt- age, total amperage load and serial number.

To install the incoming power lines, open the control box. This will require taking a phillipshead screwdriver and removing the four (4) screws on the front cover of the control box. Install 3/4” conduit into the pre-punched holes in the back of the con- trol box. Route power wires and connect to power block and grounding lug. Install the service wires (L1, L2, and L3 (3 phase only)) to the appropriate terminals as they are marked on the terminal block. Install the grounding wire into the lug pro- vided. Tighten the connections. It is recommended that “DE-OX” or another similar anti-oxidation agent be used on all power connections.

Power Block

Ground Lug

Incoming Power Connection

VOLTAGE CHECK: Ensure that the power switch is in the OFF position and

apply power to the dishmachine. Check the incoming power at the terminal block and ensure it corresponds to the voltage list- ed on the data plate. If not, contact a qualified service agency to examine the problem. Do not run the dishmachine if the volt- age is too high or too low. Shut off the service breaker and mark it as being for the dishmachine. Advise all proper personnel of any problems and of the location of the service breaker. Replace the control box cover and tighten down the screws.

Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35

Issued: 12-07-2007 Revised: N/A

10

Page 18
Image 18
Jackson Tempstar Series technical manual Power Block

Tempstar Series specifications

The Jackson Tempstar Series is a line of high-performance heating and cooling systems designed to provide reliable temperature control for both residential and commercial applications. Known for their energy efficiency, advanced technology, and durable construction, the Tempstar Series offers a range of models to fit various needs and preferences.

One of the standout features of the Tempstar Series is its impressive SEER (Seasonal Energy Efficiency Ratio) and AFUE (Annual Fuel Utilization Efficiency) ratings, which indicate that these systems consume less energy compared to traditional heating and cooling units. This not only helps homeowners save on energy bills but also reduces their environmental footprint. The use of variable-speed technology in many models allows for more precise temperature control and quieter operation, contributing to overall comfort and efficiency.

The Tempstar Series incorporates advanced compressor technology, including the use of scroll compressors that provide smooth and efficient operation. This design reduces vibrations and noise, enhancing the overall user experience. In addition, the series is equipped with multi-stage heating and cooling capabilities, which ensure consistent temperature distribution throughout the space, making it ideal for areas with varying heating requirements.

Another key characteristic of the Jackson Tempstar Series is its built-in smart features, such as Wi-Fi connectivity and compatibility with smart thermostats. This allows users to monitor and control their HVAC systems remotely, providing convenience and flexibility. Some models even feature advanced diagnostic capabilities that alert homeowners to potential maintenance issues, helping to prolong the life of the unit and reduce repair costs.

The durability of the Tempstar Series is evident in its construction, with many units featuring high-quality materials designed to withstand the elements. This includes rugged cabinets and protective coatings that resist corrosion. Furthermore, Jackson offers comprehensive warranties on their products, providing peace of mind to customers.

In conclusion, the Jackson Tempstar Series represents a commitment to quality, efficiency, and innovation in heating and cooling technology. With its energy-efficient models, advanced features, and robust design, the series provides an excellent solution for those seeking reliable climate control. Whether for a residential or commercial application, the Tempstar Series stands out as a top choice for comfort and performance.