page 10
7.0 Electrical Wiring InstructionsIMPORTANT NOTICE: The electrical wiring of this spa must meet
the requirements of the National Electrical Code/USA (NEC) and any
applicable state or local codes. The electrical circuit must be installed
by a qualified electrician and approved by a local building/electrical
inspection authority.
1. Convertible 120/240V Power Models:
• 120V “Plug-in” Operation: This spa must operate on the supplied
120V GFCI cord at its original length or must be hard-wired for
longer runs. NEVER USE AN ExTENSION CORd FOR ANy REA-
SON!
Export J-210 / J-220 1-Pump Models (50Hz)
230V/20A* 230V/30A**
Voltage: 230 VAC 230 VAC
# of Wires: 3 3
Frequency: 50Hz 50Hz
Current Draw: 15A 21A
Circuit Breaker: 20A 30A
* In the 20A configuration, the heater will not operate while the jets
pump is running in high speed. This is the factory setting.
** In the 30A configuration, the heater will operate while the jets pump
is running in high speed.
Export J-230 2-Pump Model (50Hz)
230V/20A* 230V/30A** 230V/40A***
Voltage: 230 VAC 230 VAC 240 VAC
# of Wires: 3 3 3
Frequency: 50Hz 50Hz 50Hz
Current Draw: 15A 23A 29A
Circuit Breaker: 20A 30A 40A
* In 20A configuration, the heater will not operate while either jets
pump is running in high speed. This is the factory setting. Note:
pump 2 runs only in high speed.
** In the 30A configuration, the heater will operate while one jets
pump is running in high speed. Note: pump 2 runs only in high
speed.
*** In 40A configuration, the heater will operate while both jet pumps
are running in high speed. Note: pump 2 runs only in high speed.