page 34

Standard 3-Wire 230 VAC Connection (50 Hz, 1 Phase Service)

Use copper conductors ONLY. Wire size must be appropriate per NEC and/or local codes.
BLK
BLK
BLU
BLU
BLU
BLU
BLU
BLU
BRN
BRN
BRN
BRN
BRN
BRN
BRN
Heater
2.7kW @ 230 VAC
Pressure Switch
Hi-limit/Freeze Sensor
Temperature Sensor
J2
J3
Spa Light
Transformer
230 VAC
J1 Logic Jumper SettingsJP1 1-2 oN = 20A Logic (Factory Setting)JP1 1-2 oFF = 30A LogicJP1 7-8 oN = °C Temperature Display (Factory Setting)JP1 7-8 oFF = °F Temperature Display
J20
J21
J12
J14
J16
J11
J15
J13
J17 J7 J8 J9 J10
J5
J6 Heater IN Heater oUT
F1*
K5 K7 K8J1Control Panel
THERM
SWITCH
7
5
3
1
8
6
4
2
Optional
Ozonator
O3
F1
20A
250V
SC-20
GRN
Tb1
BLUBRN 1
2
GROUND
Main Pump
HILO
HardWire Only
18.0 J-210/J-220 Export Circuit Diagram (50Hz)

This wiring diagram is used for the J-210/J-220 Export 230 VAC (50Hz)

dedicated power models.