STEP 2. ROUGH-IN PLUMBING

A.Install water lines and rough plumbing. Valve should be located between 36" and 48" from the floor. Use blocking and secure with pipe straps.

B.If stationary shower is used, install shower riser. Suggested shower head location is 78" from the floor (above the endwall).

C.The locations of the valves, mixers, and shower head should be determined before the walls are placed in position. Where access to connections is limited, allow enough flexibility in the supply lines for easier position- ing of the valves after the unit is in place.

From stable reference points such as subfloor and front of the double studs, measure and note the locations of the valves, shower head arm and connec- tion for body spray jets.

STEP 3

Install Shower Base per Shower Base Instructions.

A.For proper fit and installation of the custom shower system it is imperative that the shower base is level on all sides and the wall structure is plumb.

NOTE: Watertight installation of the drain is the installer’s responsibility. Drain leakage is excluded from the Jacuzzi Whirlpool Bath warranty of this product. (See “Drain Installation Instructions” provided with drain.)

ROUGH-IN PLUMBING DETAILS

BLOCKING

TO SHOWER HEAD

TO BODY SPRAY JETS WALL

(IF NEO WALL IS EQUIPPED WITH JETS)

OPTICA 300

 

 

MIXER AND

 

78"

TRANSFER

 

VALVE

 

(FOR FIXED

 

 

SHOWER

 

 

HEAD)

12" CLEARANCE

36" MIN.

FOR PLUMBING

48" MAX.

AT SEATWALL

 

 

24"

CENTERLINE

SUPPLY LINES

 

 

SUGGESTED PLUMBING LAYOUT

OPTICA 300 CONNECTIONS

 

(REVERSE FOR LEFT HAND SEAT WALL VERSION)

TO SHOWER HEAD OR HAND HELD SHOWER

 

TO BODY SPRAY WALL

MxF ADAPTER (3)

LINE TO WALL

 

COPPER GASKET (4)

BAR SHOWER

 

 

HEAD OR

TRANSFER

 

SHOWER

 

VALVE

 

HEAD

 

 

 

LINE TO BODY

 

 

SPRAY JETS

 

 

WALL (IF BACK

 

 

WALL IS

 

LEFT-HAND

EQUIPPED

 

WITH JETS)

 

THREAD TO

 

 

SWEAT ADAPTER

OPTICA 300

 

COPPER PIPE

MIXER/

HOT IN

TRANSFER

 

 

VALVE

 

COLD IN

HOT

 

 

 

WATER

 

 

SUPPLY

 

MIXER VALVE

COLD

 

 

 

WATER

 

 

SUPPLY

 

 

Page 3
Image 3