CV-A1-20

7.2. CV-A1-20 RS-232C command list.

 

 

Command Name

Format

 

Parameter

 

 

Remarks

 

A – General settings and useful commands

 

 

 

 

EB

 

Echo Back

EB=[Param.]<CR><LF>

0=Echo off

1=Echo on

 

Off at power up

ST

 

Camera Status request

ST?<CR><LF>

 

 

 

Actual setting

HP

 

Online Help request

HP?<CR><LF>

 

 

 

Command list

VN

 

Firmware version

VN?<CR><LF>

 

 

 

3 letter version

ID

 

Camera ID request

ID?<CR><LF>

 

 

 

10 characters *3)

MD

 

Model name request

MD?<CR><LF>

 

 

 

10 characters *3)

UD

 

User ID

UD= Param. <CR><LF>

Save and load user text

 

 

 

 

 

[

]

 

 

 

16 characters *3)

 

B – Timing and shutter related commands

 

 

 

 

SC

 

Scanning format

SC=[Param.]<CR><LF>

0=full frame

1=1/2 partial

 

 

 

 

 

 

 

2=1/3 partial

3=1/6 partial

 

 

TR

 

Trigger mode

TR=[Param.]<CR><LF>

0=normal

1=Edge

 

 

 

 

 

 

 

2=Pulse width

3=Frame delay

 

 

 

 

 

 

 

4=Long time

5=Start/stop

 

 

 

 

 

 

 

6=Smearless

 

 

 

SM

 

Shutter mode

SM=[Param.]<CR><LF>

0=Normal

1=Programmab.

 

 

SH

 

Shutter speed

SH=[Param.]<CR><LF>

0=Off

1=1/21

 

All16 step is valid

 

 

 

 

 

2=1/42

3=1/70

 

in normal trigger

 

 

 

 

 

4=1/175

5=1/349

 

mode.

 

 

 

 

 

 

 

 

 

 

 

 

6=1/698

7=1/1397

 

In all trigger

 

 

 

 

 

8=1/2794

9=1/5587

 

modes shutter

 

 

 

 

 

10=1/14,000

11=1/28,000

 

speeds higher

 

 

 

 

 

12=1/56,000

13=1/84,000

 

than 9 will result

 

 

 

 

 

 

in 1/8381

 

 

 

 

 

14=1/112,000

15=1/140,000

 

 

PE

 

Programmable expos.

PE= Param. <CR><LF>

0=1.3 H, 1=1.3H

1023=1023.3 H

 

 

 

 

 

[

]

 

 

 

H= 83.6 sec

BI

 

Binning

BI=[Param.]<CR><LF>

0=off

1=vertical

 

*1)

 

 

 

 

 

2=horizontal

3=hor. + ver.

 

 

HC

 

HD accumulation

HC=[Param.]<CR><LF>

0=H synchron

1=a-synchron

 

a-sync. only for

 

 

 

 

 

accumulation

accumulation

 

TR=1 and TR=3

 

C – Signals and polarity

 

 

 

 

 

 

SO

 

Sync signal

SO=[Param.]<CR><LF>

0=no sync

1=sync on video

 

 

PC

 

Pixel clock

PC=[Param.]<CR><LF>

0=no clock out

1=clock out

 

Should be off

 

 

 

 

 

 

 

 

when not used

EW

 

EEN/WEN

EW=[Param.]<CR><LF>

0= EEN out

1=WEN out

 

Pin#6 on 6 pin

TP

 

Trigger polarity

TP=[Param.]<CR><LF>

0= active low

1= active high

 

*2)

WP

 

WEN polarity

WP=[Param.]<CR><LF>

0= active low

1= active high

 

 

 

D – Gain and analogue signals setting

 

 

 

 

 

AS

 

AGC Switch

AS=[Param.]<CR><LF>

0=AGC off

1=AGC on

 

0= manual gain

AG

 

AGC Level

AG=[Param.]<CR><LF>

0=low

255=high

 

Range 0 to 255

GA

 

Manual gain Level

GA=[Param.]<CR><LF>

0=low

255=high

 

Range 0 to 255

RP

 

Rear Potentiometer

RP=[Param.]<CR><LF>

0=manual gain

1=rear potm.

 

 

SU

 

Setup Level

SU=[Param.]<CR><LF>

0=low

255=high

 

Range 0 to 255

WC

 

White clip Level

WC=[Param.]<CR><LF>

0=low

255=high

 

Range 0 to 255

GS

 

Gamma Select

GS=[Param.]<CR><LF>

0=gamma 1

1=gamma 0.45

 

 

 

E – Saving and loading data in EEPROM

 

 

 

 

LD

 

Load settings from

LD=[Param.]<CR><LF>

0=Factory data

1=User 1 area

 

Latest used data

 

 

camera EEPROM

 

 

2=User 2 area

3=User 3 area

 

area becomes

 

 

 

 

 

 

 

 

default at next

 

 

 

 

 

 

 

 

power up

SA

 

Save settings to

SA=[Param.]<CR><LF>

1=User 1 area

2=User 2 area

 

 

 

 

camera EEPROM

 

 

3=User 3 area

 

 

 

EA

 

EEPROM area request

EA?<CR><LF>

 

 

 

Return latest used

 

 

 

 

 

 

 

 

area

*1) The internal pixel clock is not changed in H binning (BI=2 and BI=3). To keep the aspect ratio correct, divided the clock by 2 in the frame grabber.

*2) If positive logic is used (TP=1), the first trigger pulse after power up will be ignored.

*3) Functions implemented from s/no E121231.

- 18 -

Page 19
Image 19
JAI operation manual CV-A1-20 RS-232C command list, Timing and shutter related commands