CV-A1-20

7.4. Internal Switch and Jumper Settings

For VD and HD input/output and termination refer to “6.2. Input-output of HD/VD Signals.” For alternative connections of pin #10 and #11 on 12-pin connector, jumper JP1, JP2, JP3, JP4 and JP5 can be used. Refer “5.3. Input and Output Circuits.”

Jumper setting for alternative pin configuration for M-series camera emulating is shown below.

Pin #

Function

JP2

JP3

JP5

JP1

JP4

Remarks

9

PCLK out

Short

 

 

 

 

Factory default setting (EIA-J standard)

9

No connection

Open

 

 

 

 

 

10

WEN out

 

Open

Short

 

 

Factory default setting (EIA-J standard)

10

Ground

 

Short

Open

 

 

 

11

Ext. trigger in

 

 

 

Open

Short

Factory default setting (EIA-J standard)

11

+12 Volt in/out

 

 

 

Short

Open

Warning! +12 volt power out here.

Fuse

Fig. 27. Jumper positions.

8. External Appearance and Dimensions

Fig. 28. Dimensions

- 20 -

Page 21
Image 21
JAI CV-A1-20 operation manual External Appearance and Dimensions, Internal Switch and Jumper Settings