CV-M50IR

10. Specifications

Scanning system

CCIR 625 lines

EIA 525 lines

 

25 frames/sec.

30 frames/sec.

CCD sensor

Monochrome 1/2" Hyper HAD IT CCD

Sensing area

6.6 mm (h) x 4.8 mm (v)

Effective pixels

752 (h) x 582 (v)

768 (h) x 494 (v)

Elements in video output

737 (h) x 575 (v)

758 (h) x 486 (v)

Cell size

8.6 (h) x 8.3 (v) µm

8.4 (h) x 9.8 (v) µm

Resolution (horizontal)

560 TV lines

570 TV lines

Resolution (vertical)

575 TV lines

485 TV lines

Sensitivity on sensor

 

0.01 lx

S/N ratio

>59 dB (AGC off, Gamma 1)

Video output

Composite VS signal 1.0 Vpp, 75 Ohm

Gamma

 

0.45 – 1.0

Gain

Manual – Automatic. 0 to +15 dB by potentiometer or AGC

Scanning

2:1 interlace – non-interlace

Accumulation

 

Field – frame

Synchronization

Int. X-tal. Ext HD/VD or random trigger

HD sync. input/output

 

4V, 75 Ohm*

VD sync. input/output

 

4V, 75 Ohm*

Trigger input

 

4V, 75 Ohm*

Trigger input duration

 

>HD interval

WEN output (write enable)

 

4V, 75 Ohm

EEN output (exposure enable)

 

4V, 75 Ohm

Pixel clock output (optional)

 

4V, 75 Ohm sine

Normal shutter

Off, 1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4500, 1/10,000 sec.

Edge pre-select shutter

1/60, 1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4500, 1/10,000 sec.

Pulse width controlled shutter

>1 H (64 usec.) to <60 msec.

Start/stop trigger shutter

1/77 sec to 1/10,000 sec.

Long time exposure

1 field to . Duration between ext. VD pulses

Operating temperature

 

-5°C to +45°C

Humidity

20 – 80% non-condensing

Storage temp./humidity

-25°C to 60°C/20 - 90%

Power

 

12V DC ±10%. 2.5W

Lens mount

 

C-mount

Dimensions

40 x 50 x 80 mm (HxWxD)

Mass

 

230 g

*HD sync., VD sync./(Trigger) input or output by internal jumpers. Factory setting: HD/VD input. Inputs TTL or 75 Ohm terminated by internal jumpers. Factory setting: 75 Ohm terminated.

Note: Above specifications are subject to change without notice.

10.1. Spectral Sensitivity

Relative response

1.0

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0

400 500 600 700 800 900 1000

Wave length (nm)

- 20 -

Page 21
Image 21
JAI CV-M50IR operation manual Specifications, Spectral Sensitivity